Abstract: In the rapidly growing population, the requirement of electrical power is increasing day by day. In order to meet the needs, we need to generate the power using alternate method. In this paper, a presentable approach is developed by analysis and can be implemented by utilizing heat energy, which is generated in numerous ways in some of the rural areas in India. The thermoelectric generator unit will be developed by combing with control circuits and converts, which is used to light the LED lamps. The temperature difference which is available in the kitchens, especially the exhaust pipes/chimneys of wooden fire stoves, where more heat is dissipated into the atmosphere, can be utilized for electrical power generation. Hence, the temperature rise of surroundings atmosphere can be reduced.
Abstract: Natural ventilation systems have increasingly been the subject of research due to rising energetic consumption within the building sector and increased environmental awareness. In the last two decades, the mounting concern of greenhouse gas emissions and the need for an efficient passive ventilation system have driven the development of new alternative passive technologies such as ventilated facades, trombe walls or solar chimneys. The objective of the study is the assessment of PCM panels in an in situ solar chimney for the establishment of a numerical model. The PCM integrated solar chimney shows slight performance improvement in terms of mass flow rate and external temperature and outlet temperature difference. An increase of 11.3659 m3/h can be observed during low wind speed periods. Additionally, the surface temperature across the chimney goes beyond 45 °C and allows the activation of PCM panels.
Abstract: Background: HIV/AIDS is leading to the loss of labor through sickness and subsequent death, this is leading to the neglect of farm and off-farm activities, with the subsequent loss of potential income and food security. The situation is sensitive to seasonal labour peaks in agriculture. This study was done to determine the impact of high HIV prevalence in farming systems and food security in Pala Bondo District, Kenya. Methods: In this study, 386 respondents were randomly chosen in Pala Sub-Location. The respondents and key informants were interviewed using structured questionnaire. The data were entered and analyzed using SPSS version 16. Results: It was established that majority of respondents (67%) were between 18 and 35 years {χ2 = (1, N = 386) = 13.430, p = 0.000} (chimney effect). The study also established that 83.5% of respondents were married {χ2 = (1, N= 370) = 166.277 p = 0.000} and predominant occupation being farming and fishing (61%), while 52.8% of farm labour was by hand, 26% by oxen, and 4.9% mechanized. 73.2% of respondents only farm 0.25 to 2 acres, 48% mentioned lack of labour in land preparation {χ2 ((1,N = 321) = 113.146, p = 0.000), in planting {χ2 (1, N = 321) = 29.28, p = 0.000}. Majority of respondents lack food from January to June, during which 93% buy food. Conclusion: The high HIV prevalence in Pala has affected the farm labour leading to food insecurity.
Abstract: In this paper, a procedure for the evaluation of seismic behavior of slender masonry structures (towers, bell towers, chimneys, minarets, etc.) is presented. The presented procedure is based on a full three-dimensional modal analyses and frequency measurements. As well-known, masonry is a composite material formed by bricks, or stone blocks, and mortar arranged more or less regularly and adopted for many centuries as structural material. Dynamic actions may represent the major risk of collapse of brickworks, and despite the progress achieved so far in science and mechanics; the assessment of their seismic performance remains a challenging task. Then, reliable physical and numerical models are worthy of recommendation. In this paper, attention is paid to the historical bell tower of the Basilica of Santa Maria Gloriosa dei Frari - usually called Frari - one of the greatest churches in Venice, Italy.
Abstract: Result from the constant dwindle in natural resources,
the alternative way to reduce the costs in our daily life would be urgent
to be found in the near future. As the ancient technique based on the
theory of solar chimney since roman times, the double-skin façade are
simply composed of two large glass panels in purpose of daylighting
and also natural ventilation in the daytime. Double-skin façade is
generally installed on the exterior side of buildings as function as the
window, so there is always a huge amount of passive solar energy the
façade would receive to induce the airflow every sunny day. Therefore,
this article imposes a domestic double-skin window for residential
usage and attempts to improve the volume flow rate inside the cavity
between the panels by the frame geometry design, the installation of
outlet guide plate and the solar energy collection system. Note that the
numerical analyses are applied to investigate the characteristics of flow
field, and the boundary conditions in the simulation are totally based
on the practical experiment of the original prototype. Then we
redesign the prototype from the knowledge of the numerical results
and fluid dynamic theory, and later the experiments of modified
prototype will be conducted to verify the simulation results. The
velocities at the inlet of each case are increase by 5%, 45% and 15%
from the experimental data, and also the numerical simulation results
reported 20% improvement in volume flow rate both for the frame
geometry design and installation of outlet guide plate.
Abstract: This research presents the design and analysis of solar
air-conditioning systems particularly solar chimney which is a
passive strategy for natural ventilation, and demonstrates the
structures of these systems’ using Computational Fluid Dynamic
(CFD) and finally compares the results with several examples, which
have been studied experimentally and carried out previously. In order
to improve the performance of solar chimney system, highly efficient
sub-system components are considered for the design. The general
purpose of the research is to understand how efficiently solar
chimney systems generate cooling, and is to improve the efficient of
such systems for integration with existing and future domestic
buildings.
Abstract: This paper studies a mathematical model based on the
integral equations for dynamic analyzes numerical investigations of a
non-uniform or multi-material composite beam. The beam is
subjected to a sub-tangential follower force and elastic foundation.
The boundary conditions are represented by generalized
parameterized fixations by the linear and rotary springs. A
mathematical formula based on Euler-Bernoulli beam theory is
presented for beams with variable cross-sections. The non-uniform
section introduces non-uniformity in the rigidity and inertia of beams
and consequently, more complicated equilibrium who governs the
equation. Using the boundary element method and radial basis
functions, the equation of motion is reduced to an algebro-differential
system related to internal and boundary unknowns. A generalized
formula for the deflection, the slope, the moment and the shear force
are presented. The free vibration of non-uniform loaded beams is
formulated in a compact matrix form and all needed matrices are
explicitly given. The dynamic stability analysis of slender beam is
illustrated numerically based on the coalescence criterion. A realistic
case related to an industrial chimney is investigated.
Abstract: This paper presents the results obtained by numerical
simulation using the software ANSYS CFX-CFD for the air
pollutants dispersion in the atmosphere coming from the evacuation
of combustion gases resulting from the fuel combustion in an electric
thermal power plant. The model uses the Navier-Stokes equation to
simulate the dispersion of pollutants in the atmosphere. It is
considered as important factors in elaboration of simulation the
atmospheric conditions (pressure, temperature, wind speed, wind
direction), the exhaust velocity of the combustion gases, chimney
height and the obstacles (buildings). Using the air quality monitoring
stations it is measured the concentrations of main pollutants (SO2,
NOx and PM). The pollutants were monitored over a period of 3
months, after that the average concentration are calculated, which is
used by the software. The concentrations are: 8.915 μg/m3 (NOx),
9.587 μg/m3 (SO2) and 42 μg/m3 (PM). A comparison of test data
with simulation results demonstrated that CFX was able to describe
the dispersion of the pollutant as well the concentration of this
pollutants in the atmosphere.
Abstract: A three-dimensional numerical model of
thermoelectric generator (TEG) modules attached to a large chimney
plate is proposed and solved numerically using a control volume based
finite difference formulation. The TEG module consists of a
thermoelectric generator, an elliptical pin-fin heat sink, and a cold
plate for water cooling. In the chimney, the temperature of flue gases is
450-650K. Although the TEG hot-side temperature and thus the
electric power output can be increased by inserting an elliptical pin-fin
heat sink into the chimney tunnel to increase the heat transfer area, the
pin fin heat sink would cause extra pumping power at the same time.
The main purpose of this study is to analyze the effects of geometrical
parameters on the electric power output and chimney pressure drop
characteristics. The effects of different operating conditions, including
various inlet velocities (Vin= 1, 3, 5 m/s), inlet temperatures (Tgas = 450,
550, 650K) and different fin height (0 to 150 mm) are discussed in
detail. The predicted numerical data for the power vs. current (P-I)
curve are in good agreement (within 11%) with the experimental data.
Abstract: Smoke discharging is a main reason of air pollution
problem from industrial plants. The obstacle of a building has an
affect with the air pollutant discharge. In this research, a mathematical
model of the smoke dispersion from two sources and one source with
a structural obstacle is considered. The governing equation of the
model is an isothermal mass transfer model in a viscous fluid. The
finite element method is used to approximate the solutions of the
model. The triangular linear elements have been used for discretising
the domain, and time integration has been carried out by semi-implicit
finite difference method. The simulations of smoke dispersion in
cases of one chimney and two chimneys are presented. The maximum
calculated smoke concentration of both cases are compared. It is then
used to make the decision for smoke discharging and air pollutant
control problems on industrial area.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: Natural ventilation is an important means to improve indoor thermal comfort and reduce the energy consumption. A solar chimney system is an enhancing natural draft device, which uses solar radiation to heat the air inside the chimney, thereby converting the thermal energy into kinetic energy. The present study considered some parameters such as chimney width and solar intensity, which were believed to have a significant effect on space ventilation. Fluent CFD software was used to predict buoyant air flow and flow rates in the cavities. The results were compared with available published experimental and theoretical data from the literature. There was an acceptable trend match between the present results and the published data for the room air change per hour, ACH. Further, it was noticed that the solar intensity has a more significant effect on ACH.
Abstract: Majority of pepper farmers in Malaysia are using the
open-sun method for drying the pepper berries. This method is time
consuming and exposed the berries to rain and contamination. A
maintenance-friendly and properly enclosed dryer is therefore
desired. A dryer design with a solar collector and a chimney was
studied and adapted to suit the needs of small-scale pepper farmers in
Malaysia. The dryer will provide an environment with an optimum
operating temperature meant for drying pepper berries. The dryer
model was evaluated by using commercially available computational
fluid dynamic (CFD) software in order to understand the heat and
mass transfer inside the dryer. Natural convection was the only mode
of heat transportation considered in this study as in accordance to the
idea of having a simple and maintenance-friendly design. To
accommodate the effect of low buoyancy found in natural convection
driers, a biomass burner was integrated into the solar dryer design.