Abstract: The characteristics of physiological blood flow in human carotid arterial bifurcation model have been numerically studied using a fully coupled fluid-structure interaction (FSI) analysis. This computational model with the fluid-structure interaction is constructed to investigate the flow characteristics and wall shear stress in the carotid artery. As the flow begins to decelerate after the peak flow, a large recirculation zone develops at the non-divider wall of both internal carotid artery (ICA) and external carotid artery (ECA) in FSI model due to the elastic energy stored in the expanding compliant wall. The calculated difference in wall shear stress (WSS) in both Non-FSI and FSI models is a range of between 5 and 11% at the mean WSS. The low WSS corresponds to regions of carotid artery that are more susceptible to atherosclerosis.
Abstract: Alzheimer is known as the loss of mental functions
such as thinking, memory, and reasoning that is severe enough to
interfere with a person's daily functioning. The appearance of
Alzheimer Disease symptoms (AD) are resulted based on which part
of the brain has a variety of infection or damage. In this case, the
MRI is the best biomedical instrumentation can be ever used to
discover the AD existence. Therefore, this paper proposed a fusion
method to distinguish between the normal and (AD) MRIs. In this
combined method around 27 MRIs collected from Jordanian
Hospitals are analyzed based on the use of Low pass -morphological
filters to get the extracted statistical outputs through intensity
histogram to be employed by the descriptive box plot. Also, the
artificial neural network (ANN) is applied to test the performance of
this approach. Finally, the obtained result of t-test with confidence
accuracy (95%) has compared with classification accuracy of ANN
(100 %). The robust of the developed method can be considered
effectively to diagnose and determine the type of AD image.
Abstract: The influence of physical (external added weight) and
neurophysiological (fatigue) factors on static and dynamic balance in
sport related activities was typified statically by the Romberg test
(one foot flat, eyes open) and dynamically by jumping and hopping
in both horizontal and vertical directions. Twenty healthy males were
participated in this study. In Static condition, added weight increased
body-s inertia and therefore decreased body sway in AP direction
though not significantly. Dynamically, added weight significantly
increased body sway in both ML and AP directions, indicating
instability, and the use of the counter rotating segments mechanism to
maintain balance was demonstrated. Fatigue on the other hand
significantly increased body sway during static balance as a
neurophysiological adaptation primarily to the inverted pendulum
mechanism. Dynamically, fatigue significantly increased body sway
in both ML and AP directions again indicating instability but with a
greater use of counter rotating segments mechanism. Differential
adaptations for each of the two balance mechanisms (inverted
pendulum and counter rotating segments) were found between one
foot flat and two feet flat dynamic conditions, as participants relied
more heavily on the first in the one foot flat conditions and relied
more on the second in the two feet flat conditions.
Abstract: En bloc assumes modeling all phases of the orthostatic test with the only one mathematical model, which allows the complex parametric view of orthostatic response. The work presents the implementation of a mathematical model for processing of the measurements of systolic, diastolic blood pressure and heart rate performed on volunteers during orthostatic test. The original assumption of model hypothesis that every postural change means only one Stressor, did not complying with the measurements of physiological circulation factor-time profiles. Results of the identification support the hypothesis that second postural change of orthostatic test causes induced Stressors, with the observation of a physiological regulation mechanism. Maximal demonstrations are on the heart rate and diastolic blood pressure-time profile, minimal are for the measurements of the systolic blood pressure. Presented study gives a new view on orthostatic test with impact on clinical practice.