Abstract: Various models have been derived by studying large number of completed software projects from various organizations and applications to explore how project sizes mapped into project effort. But, still there is a need to prediction accuracy of the models. As Neuro-fuzzy based system is able to approximate the non-linear function with more precision. So, Neuro-Fuzzy system is used as a soft computing approach to generate model by formulating the relationship based on its training. In this paper, Neuro-Fuzzy technique is used for software estimation modeling of on NASA software project data and performance of the developed models are compared with the Halstead, Walston-Felix, Bailey-Basili and Doty Models mentioned in the literature.
Abstract: The clinical usefulness of heart rate variability is
limited to the range of Holter monitoring software available. These
software algorithms require a normal sinus rhythm to accurately
acquire heart rate variability (HRV) measures in the frequency
domain. Premature ventricular contractions (PVC) or more
commonly referred to as ectopic beats, frequent in heart failure,
hinder this analysis and introduce ambiguity. This investigation
demonstrates an algorithm to automatically detect ectopic beats by
analyzing discrete wavelet transform coefficients. Two techniques
for filtering and replacing the ectopic beats from the RR signal are
compared. One technique applies wavelet hard thresholding
techniques and another applies linear interpolation to replace ectopic
cycles. The results demonstrate through simulation, and signals
acquired from a 24hr ambulatory recorder, that these techniques can
accurately detect PVC-s and remove the noise and leakage effects
produced by ectopic cycles retaining smooth spectra with the
minimum of error.
Abstract: One of the essential requirements of a realistic
surgical simulator is to reproduce haptic sensations due to the
interactions in the virtual environment. However, the interaction need
to be performed in real-time, since a delay between the user action
and the system reaction reduces the immersion sensation. In this
paper, a prototype of a coronary stent implant simulator is present;
this system allows real-time interactions with an artery by means of a
specific haptic device. To improve the realism of the simulation, the
building of the virtual environment is based on real patients- images
and a Web Portal is used to search in the geographically remote
medical centres a virtual environment with specific features in terms
of pathology or anatomy. The functional architecture of the system
defines several Medical Centres in which virtual environments built
from the real patients- images and related metadata with specific
features in terms of pathology or anatomy are stored. The searched
data are downloaded from the Medical Centre to the Training Centre
provided with a specific haptic device and with the software
necessary both to manage the interaction in the virtual environment.
After the integration of the virtual environment in the simulation
system it is possible to perform training on the specific surgical
procedure.