Abstract: Sedimentation of magnetorheological (MR) fluid affects its working. MR fluid is a smart fluid that has unique qualities such as quick responsiveness and easy controllability. It is used in the MR damper, MR brake, and MR clutch. In this work effect of sedimentation on torque transmission in the shear mode operated MR clutch is investigated. A test rig is developed to test the impact of sedimentation on torque transmission in the MR clutch. Torque transmission capability of MR clutch has been measured under two conditions to confirm the result of sedimentation. The first experiment is done just after filling and the other after one week. It has been observed that transmission torque is decreased after sedimentation. Hence sedimentation affects the working of the MR clutch.
Abstract: International guidelines recommend removing any
artificial body in Low Earth Orbit (LEO) within 25 years from
mission completion. Among disposal strategies, electrodynamic
tethers appear to be a promising option for LEO, thanks to the
limited storage mass and the minimum interface requirements to the
host spacecraft. In particular, recent technological advances make it
feasible to deorbit large objects with tether lengths of a few kilometers
or less. To further investigate such an innovative passive system,
the European Union is currently funding the project E.T.PACK
– Electrodynamic Tether Technology for Passive Consumable-less
Deorbit Kit in the framework of the H2020 Future Emerging
Technologies (FET) Open program. The project focuses on the design
of an end of life disposal kit for LEO satellites. This kit aims to
deploy a taped tether that can be activated at the spacecraft end of life
to perform autonomous deorbit within the international guidelines.
In this paper, the orbital performance of the E.T.PACK deorbiting
kit is compared to other disposal methods. Besides, the orbital decay
prediction is parametrized as a function of spacecraft mass and tether
system performance. Different values of length, width, and thickness
of the tether will be evaluated for various scenarios (i.e., different
initial orbital parameters). The results will be compared to other
end-of-life disposal methods with similar allocated resources. The
analysis of the more innovative system’s performance with the tape
coated with a thermionic material, which has a low work-function
(LWT), for which no active component for the cathode is required,
will also be briefly discussed. The results show that the electrodynamic tether option can be a
competitive and performant solution for satellite disposal compared
to other deorbit technologies.
Abstract: In today's world, with increasing environmental awareness, firms are facing severe pressure from various stakeholders, including the government and customers, to reduce their harmful effects on the environment. Over the past few decades, the increasing effects of global warming, climate change, waste, and air pollution have increased the global attention of experts to the issue of the green supply chain and led them to the optimal solution for greenery. Green supply chain management (GSCM) plays an important role in motivating the sustainability of the organization. With increasing environmental concerns, the main objective of the research is to use system thinking methodology and Vensim software for designing a dynamic system model for green supply chain and observing behaviors. Using this methodology, we look for the effects of a green supply chain structure on the behavioral dynamics of output variables. We try to simulate the complexity of GSCM in a period of 30 months and observe the complexity of behaviors of variables including sustainability, providing green products, and reducing energy consumption, and consequently reducing sample pollution.
Abstract: Loosening of bolted joints in rotating machines can adversely affect their performance, cause mechanical damage, and lead to injuries. In this paper, two potential loosening phenomena in rotating applications are discussed. First, ‘precession,’ is governed by thread/nut contact forces, while the second is based on inertial effects of the fastened assembly. These mechanisms are reviewed within the context of historical usage of left-handed fasteners in rotating machines which appears absent in the literature and common machine design texts. Historically, to prevent loosening of wheel nuts, vehicle manufacturers have used right-handed and left-handed threads on different sides of the vehicle, but most modern vehicles have abandoned this custom and only use right-handed, tapered lug nuts on all sides of the vehicle. Other classical machines such as the bicycle continue to use different handed threads on each side while other machines such as, bench grinders, circular saws and brush cutters still use left-handed threads to fasten rotating components. Despite the continued use of left-handed fasteners, the rationale and analysis of left-handed threads to mitigate self-loosening of fasteners in rotating applications is not commonly, if at all, discussed in the literature or design textbooks. Without scientific literature to support these design selections, these implementations may be the result of experimental findings or aged institutional knowledge. Based on a review of rotating applications, historical documents and mechanical design references, a formal study of the paradoxical nature of left-handed threads in various applications is merited.
Abstract: Biosensors play a significant role in the healthcare
sectors, scientific and technological progress. Developing electrodes
that are easy to manufacture and deliver better electrochemical
performance is advantageous for diagnostics and biosensing. They
can be implemented extensively in various analytical tasks such as
drug discovery, food safety, medical diagnostics, process controls,
security and defence, in addition to environmental monitoring.
Development of biosensors aims to create high-performance
electrochemical electrodes for diagnostics and biosensing. A
biosensor is a device that inspects the biological and chemical
reactions generated by the biological sample. A biosensor carries
out biological detection via a linked transducer and transmits the
biological response into an electrical signal; stability, selectivity,
and sensitivity are the dynamic and static characteristics that affect
and dictate the quality and performance of biosensors. In this
research, a developed experimental study for laser scribing technique
for graphene oxide inside a vacuum chamber for processing of
graphene oxide is presented. The processing of graphene oxide (GO)
was achieved using the laser scribing technique. The effect of the
laser scribing on the reduction of GO was investigated under two
conditions: atmosphere and vacuum. GO solvent was coated onto a
LightScribe DVD. The laser scribing technique was applied to reduce
GO layers to generate rGO. The micro-details for the morphological
structures of rGO and GO were visualised using scanning electron
microscopy (SEM) and Raman spectroscopy so that they could
be examined. The first electrode was a traditional graphene-based
electrode model, made under normal atmospheric conditions, whereas
the second model was a developed graphene electrode fabricated
under a vacuum state using a vacuum chamber. The purpose was
to control the vacuum conditions, such as the air pressure and the
temperature during the fabrication process. The parameters to be
assessed include the layer thickness and the continuous environment.
Results presented show high accuracy and repeatability achieving low
cost productivity.