Abstract: This paper presents the development of a compact, portable and easy to handle solar cell characterization device. The presented device reduces the effort and cost of single solar cell characterization to a minimum. It enables realistic characterization of cells under sunlight within minutes. In the field of photovoltaic research the common way to characterize a single solar cell or a module is, to measure the current voltage curve. With this characteristic the performance and the degradation rate can be defined which are important for the consumer or developer. The paper consists of the system design description, a summary of the measurement results and an outline for further developments.
Abstract: There is a great problem in testing and investigations the reliability of different type of transformers insulation materials. It summarized in how to create and simulate the real conditions of working transformer and testing its insulation materials for Partial Discharge PD, typically as in the working mode. A lot of tests may give untrue results as the physical behavior of the insulation material differs under tests from its working condition. In this work, the real working conditions were simulated, and a large number of specimens have been tested. The investigations first stage, begin with choosing samples of different types of insulation materials (papers, pressboards, etc.). The second stage, the samples were dried in ovens at 105 C0and 0.01bar for 48 hours, and then impregnated with dried and gasless oil (the water content less than 6 ppm.) at 105 C0and 0.01bar for 48 hours, after so specimen cooling at room pressure and temperature for 24 hours. The third stage is investigating PD for the samples using ICM PD measuring device. After that, a continuous test on oil-impregnated insulation materials (paper, pressboards) was developed, and the phase resolved partial discharge pattern of PD signals was measured. The important of this work in providing the industrial sector with trusted high accurate measuring results based on real simulated working conditions. All the PD patterns (results) associated with a discharge produced in well-controlled laboratory condition. They compared with other previous and other laboratory results. In addition, the influence of different temperatures condition on the partial discharge activities was studied.
Abstract: There is numerous non-invasive blood glucose measurement technique developed by researchers, and near infrared (NIR) is the potential technique nowadays. However, there are some disagreements on the optimal wavelength range that is suitable to be used as the reference of the glucose substance in the blood. This paper focuses on the experimental data collection technique and also the analysis method used to analyze the data gained from the experiment. The selection of suitable linear and non-linear model structure is essential in prediction system, as the system developed need to be conceivably accurate.
Abstract: This paper presents a SAC-OCDMA code with zero cross correlation property to minimize the Multiple Access Interface (MAI) as New Zero Cross Correlation code (NZCC), which is found to be more scalable compared to the other existing SAC-OCDMA codes. This NZCC code is constructed using address segment and data segment. In this work, the proposed NZCC code is implemented in an optical system using the Opti-System software for the spectral amplitude coded optical code-division multiple-access (SAC-OCDMA) scheme. The main contribution of the proposed NZCC code is the zero cross correlation, which reduces both the MAI and PIIN noises. The proposed NZCC code reveals properties of minimum cross-correlation, flexibility in selecting the code parameters and supports a large number of users, combined with high data rate and longer fiber length. Simulation results reveal that the optical code division multiple access system based on the proposed NZCC code accommodates maximum number of simultaneous users with higher data rate transmission, lower Bit Error Rates (BER) and longer travelling distance without any signal quality degradation, as compared to the former existing SAC-OCDMA codes.
Abstract: This paper discusses the simulation and experimental work of small Smart Grid containing ten consumers. Smart Grid is characterized by a two-way flow of real-time information and energy. RTP (Real Time Pricing) based tariff is implemented in this work to reduce peak demand, PAR (peak to average ratio) and cost of energy consumed. In the experimental work described here, working of Smart Plug, HEC (Home Energy Controller), HAN (Home Area Network) and communication link between consumers and utility server are explained. Algorithms for Smart Plug, HEC, and utility server are presented and explained in this work. After receiving the Real Time Price for different time slots of the day, HEC interacts automatically by running an algorithm which is based on Linear Programming Problem (LPP) method to find the optimal energy consumption schedule. Algorithm made for utility server can handle more than one off-peak time period during the day. Simulation and experimental work are carried out for different cases. At the end of this work, comparison between simulation results and experimental results are presented to show the effectiveness of the minimization method adopted.
Abstract: In this paper, we consider a non-identically independently distributed (non-i.i.d.) Hoyt fading single-input multiple-out put (SIMO) channel, where the transmitter sends some confidential information to the legitimate receiver in presence of an eavesdropper. We formulated the probability of non-zero secrecy mutual information; secure outage probability and average secrecy mutual information (SMI) for the SIMO wireless communication system. The calculation has been carried out using small limit argument approximation (SLAA) on zeroth-order modified Bessel function of first kind. In our proposed model, an eavesdropper observes transmissions of information through another Hoyt fading channel. First, we derived the analytical expression for non-zero secrecy mutual information. Then, we find the secure outage probability to investigate the outage behavior of the proposed model. Finally, we find the average secrecy mutual information. We consider that the channel state information (CSI) is known to legitimate receiver.
Abstract: Myoelectric control system is the fundamental
component of modern prostheses, which uses the myoelectric signals
from an individual’s muscles to control the prosthesis movements.
The surface electromyogram signal (sEMG) being noninvasive has
been used as an input to prostheses controllers for many years.
Recent technological advances has led to the development of
implantable myoelectric sensors which enable the internal
myoelectric signal (MES) to be used as input to these prostheses
controllers. The intramuscular measurement can provide focal
recordings from deep muscles of the forearm and independent signals
relatively free of crosstalk thus allowing for more independent
control sites. However, little work has been done to compare the two
inputs. In this paper we have compared the classification accuracy of
six pattern recognition based myoelectric controllers which use
surface myoelectric signals recorded using untargeted (symmetric)
surface electrode arrays to the same controllers with multichannel
intramuscular myolectric signals from targeted intramuscular
electrodes as inputs. There was no significant enhancement in the
classification accuracy as a result of using the intramuscular EMG
measurement technique when compared to the results acquired using
the surface EMG measurement technique. Impressive classification
accuracy (99%) could be achieved by optimally selecting only five
channels of surface EMG.
Abstract: In this paper, a modified Wilkinson power divider for
GSM application is presented. The quarter–wavelength microstrip
lines in the conventional Wilkinson power divider (WPD) are
replaced by one-eighth wavelength transmission line. Wilkinson
power divider is designed using λ/4 and λ/8 transmission line. It has
the operating frequency of 915 MHz which is used in the GSM
standard. The proposed Wilkinson Power Divider is designed using
the simulation tool Advanced Design System. The results of λ/8
transmission line are very close to the results of λ/4 transmission line.
The isolation loss of λ/8 transmission line is improved by introducing
a capacitor between the output ports. The proposed Wilkinson power
divider has the best return loss of greater than -10 dB and isolation
loss of -15.25 dB. The λ/8 transmission line Wilkinson power divider
has the reduced size of 53.9 percentages than λ/4 transmission line
WPD. The proposed design has simple structure, better isolation loss
and good insertion loss.
Abstract: The increase in electric power demand in face of
environmental issues has intensified the participation of renewable
energy sources such as photovoltaics, in the energy matrix of various
countries. Due to their operational characteristics, they can generate
time-varying harmonic and inter-harmonic distortions. For this
reason, the application of methods of measurement based on
traditional Fourier analysis, as proposed by IEC 61000-4-7, can
provide inaccurate results. Considering the aspects mentioned herein,
came the idea of the development of this work which aims to present
the results of a comparative evaluation between a methodology
arising from the combination of the Prony method with the Kalman
filter and another method based on the IEC 61000-4-30 and IEC
61000-4-7 standards. Employed in this study were synthetic signals
and data acquired through measurements in a 50kWp photovoltaic
installation.
Abstract: Microcantilevers are the basic MEMS devices, which
can be used as sensors, actuators and electronics can be easily built
into them. The detection principle of microcantilever sensors is based
on the measurement of change in cantilever deflection or change in its
resonance frequency. The objective of this work is to explore the
analogies between mechanical and electrical equivalent of
microcantilever beams. Normally scientists and engineers working in
MEMS use expensive software like CoventorWare, IntelliSuite,
ANSYS/Multiphysics etc. This paper indicates the need of developing
electrical equivalent of the MEMS structure and with that, one can
have a better insight on important parameters, and their interrelation of
the MEMS structure. In this work, considering the mechanical model
of microcantilever, equivalent electrical circuit is drawn and using
force-voltage analogy, it is analyzed with circuit simulation software.
By doing so, one can gain access to powerful set of intellectual tools
that have been developed for understanding electrical circuits Later
the analysis is performed using ANSYS/Multiphysics - software based
on finite element method (FEM). It is observed that both mechanical
and electrical domain results for a rectangular microcantlevers are in
agreement with each other.
Abstract: We consider fast and accurate solutions of scattering
problems by large perfectly conducting objects (PEC) formulated
by an optimization of the Method of Auxiliary Sources (MAS). We
present various techniques used to reduce the total computational cost
of the scattering problem. The first technique is based on replacing
the object by an array of finite number of small (PEC) object with the
same shape. The second solution reduces the problem on considering
only the half of the object.These t
Abstract: Direct Torque Control (DTC) is an AC drive control
method especially designed to provide fast and robust responses. In
this paper a progressive algorithm for direct torque control of threephase
induction drive system supplied by photovoltaic arrays using
voltage source inverter to control motor torque and flux with
maximum power point tracking at different level of insolation is
presented. Experimental results of the new DTC method obtained by
an experimental rapid prototype system for drives are presented.
Simulation and experimental results confirm that the proposed system
gives quick, robust torque and speed responses at constant switching
frequencies.
Abstract: This paper presents a case study of using STATCOM to enhance the performance of Al-Qatraneh 33-kV transmission line. The location of the STATCOM was identified by maintaining minimum voltage drops at the 110 load nodes. The transmission line and the 110 load nodes have been modeled by MATLAB/Simulink. The suggested STATCOM and its location will increase the transmission capability of this transmission line and overcome the overload expected in the year 2020. The annual percentage loading rise has been considered as 14.35%. A graphical representation of the line-to-line voltages and the voltage drops at different load nodes is illustrated.
Abstract: The use of wireless technology in industrial networks
has gained vast attraction in recent years. In this paper, we have
thoroughly analyzed the effect of contention window (CW) size on
the performance of IEEE 802.11-based industrial wireless networks
(IWN), from delay and reliability perspective. Results show that the
default values of CWmin, CWmax, and retry limit (RL) are far from
the optimum performance due to the industrial application
characteristics, including short packet and noisy environment. In this
paper, an adaptive CW algorithm (payload-dependent) has been
proposed to minimize the average delay. Finally a simple, but
effective CW and RL setting has been proposed for industrial
applications which outperforms the minimum-average-delay solution
from maximum delay and jitter perspective, at the cost of a little
higher average delay. Simulation results show an improvement of up
to 20%, 25%, and 30% in average delay, maximum delay and jitter
respectively.
Abstract: This paper presents the advantages of fuzzy control use in technological processes control. The paper presents a real application of the Linguistic Fuzzy-Logic Control, developed at the University of Ostrava for the control of physical models in the Intelligent Systems Laboratory. The paper presents an example of a sensitive non-linear model, such as a magnetic levitation model and obtained results which show how modern information technologies can help to solve actual technical problems. A special method based on the LFLC controller with partial components is presented in this paper followed by the method of automatic context change, which is very helpful to achieve more accurate control results. The main advantage of the used system is its robustness in changing conditions demonstrated by comparing with conventional PID controller. This technology and real models are also used as a background for problem-oriented teaching, realized at the department for master students and their collaborative as well as individual final projects.
Abstract: The energy need is growing rapidly due to the
population growth and the large new usage of power. Several works
put considerable efforts to make the electricity grid more intelligent
to reduce essentially energy consumption and provide efficiency and
reliability of power systems. The Smart Grid is a complex
architecture that covers critical devices and systems vulnerable to
significant attacks. Hence, security is a crucial factor for the success
and the wide deployment of Smart Grids. In this paper, we present
security issues of the Smart Grid architecture and we highlight open
issues that will make the Smart Grid security a challenging research
area in the future.
Abstract: The first layer of defense against data loss is the backup
data. This paper implements an agent-based network backup system
used the backup, server-storage and server-backup agent these
tripartite construction, and the snapshot and hierarchical index are
used in the NSBS. It realizes the control command and data flow
separation, balances the system load, thereby improving efficiency of
the system backup and recovery. The test results show the agent-based
network backup system can effectively improve the task-based
concurrency, reasonably allocate network bandwidth, the system
backup performance loss costs smaller and improves data recovery
efficiency by 20%.
Abstract: Multiple Input Multiple Output (MIMO) systems are
wireless systems with multiple antenna elements at both ends of the
link. Wireless communication systems demand high data rate and
spectral efficiency with increased reliability. MIMO systems have
been popular techniques to achieve these goals because increased
data rate is possible through spatial multiplexing scheme and
diversity. Spatial Multiplexing (SM) is used to achieve higher
possible throughput than diversity. In this paper, we propose a Zero-
Forcing (ZF) detection using a combination of Ordered Successive
Interference Cancellation (OSIC) and Zero Forcing using
Interference Cancellation (ZF-IC). The proposed method used an
OSIC based on Signal to Noise Ratio (SNR) ordering to get the
estimation of last symbol, then the estimated last symbol is
considered to be an input to the ZF-IC. We analyze the Bit Error Rate
(BER) performance of the proposed MIMO system over Rayleigh
Fading Channel, using Binary Phase Shift Keying (BPSK)
modulation scheme. The results show better performance than the
previous methods.
Abstract: The main issue in designing a wireless sensor network
(WSN) is the finding of a proper routing protocol that complies with
the several requirements of high reliability, short latency, scalability,
low power consumption, and many others. This paper proposes a
novel routing algorithm that complies with these design
requirements. The new routing protocol divides the WSN into several subnetworks
and each sub-network is divided into several clusters. This
division is designed to reduce the number of radio transmission and
hence decreases the power consumption. The network division may
be changed dynamically to adapt with the network changes and
allows the realization of the design requirements.