Abstract: This paper describes the smart energy monitoring system with a wireless sensor network for monitoring of electrical usage in smart house. Proposed system is composed of wireless plugs and energy control wallpad server. The wireless plug integrates an AC power socket, a relay to switch the socket ON/OFF, a Hall effect sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. We evaluated wireless plug in a laboratory, analyzed and presented energy consumption data from electrical appliances for 3 months in home.
Abstract: In this article the influence of higher frequency effects
in addition to a special damper design on the electrical behavior of a
synchronous generator main exciter machine is investigated. On the
one hand these machines are often highly stressed by harmonics from
the bridge rectifier thus facing additional eddy current losses. On the
other hand the switching may cause the excitation of dangerous
voltage peaks in resonant circuits formed by the diodes of the
rectifier and the commutation reactance of the machine. Therefore
modern rotating exciters are treated like synchronous generators
usually modeled with a second order equivalent circuit. Hence the
well known Standstill Frequency Response Test (SSFR) method is
applied to a test machine in order to determine parameters for the
simulation. With these results it is clearly shown that higher
frequencies have a strong impact on the conventional equivalent
circuit model. Because of increasing field displacement effects in the
stranded armature winding the sub-transient reactance is even smaller
than the armature leakage at high frequencies. As a matter of fact this
prevents the algorithm to find an equivalent scheme. This issue is
finally solved using Laplace transfer functions fully describing the
transient behavior at the model ports.
Abstract: Wireless Sensor Networks can be used to monitor the
physical phenomenon in such areas where human approach is nearly
impossible. Hence the limited power supply is the major constraint of
the WSNs due to the use of non-rechargeable batteries in sensor
nodes. A lot of researches are going on to reduce the energy
consumption of sensor nodes. Energy map can be used with
clustering, data dissemination and routing techniques to reduce the
power consumption of WSNs. Energy map can also be used to know
which part of the network is going to fail in near future. In this paper,
Energy map is constructed using the prediction based approach.
Adaptive alpha GM(1,1) model is used as the prediction model.
GM(1,1) is being used worldwide in many applications for predicting
future values of time series using some past values due to its high
computational efficiency and accuracy.
Abstract: One of the most challengeable issues in ESL
(Electronic System Level) design is the lack of a general modeling
scheme for on chip communication architecture. In this paper some
of the mostly used methodologies for modeling and representation of
on chip communication are investigated. Our goal is studying the
existing methods to extract the requirements of a general
representation scheme for communication architecture synthesis. The
next step, will be introducing a modeling and representation method
for being used in automatically synthesis process of on chip
communication architecture.
Abstract: In this paper, half bridge DC-DC converters with
transformer isolation presented in the literature are analyzed for highcurrent
and low-voltage applications under the same operation
conditions, and compared in terms of losses and efficiency. The
conventional and improved half-bridge DC-DC converters are
simulated, and current and voltage waveforms are obtained for input
voltage Vdc=500V, output current IO=450A, output voltage VO=38V
and switching frequency fS=20kHz. IGBTs are used as power
semiconductor switches. The power losses of the semiconductor
devices are calculated from current and voltage waveforms. From
simulation results, it is seen that the capacitor switched half bridge
converter has the best efficiency value, and can be preferred at high
power and high frequency applications.
Abstract: Many real-world optimization problems involve multiple conflicting objectives and the use of evolutionary algorithms to solve the problems has attracted much attention recently. This paper investigates the application of multi-objective optimization technique for the design of a Thyristor Controlled Series Compensator (TCSC)-based controller to enhance the performance of a power system. The design objective is to improve both rotor angle stability and system voltage profile. A Genetic Algorithm (GA) based solution technique is applied to generate a Pareto set of global optimal solutions to the given multi-objective optimisation problem. Further, a fuzzy-based membership value assignment method is employed to choose the best compromise solution from the obtained Pareto solution set. Simulation results are presented to show the effectiveness and robustness of the proposed approach.
Abstract: In this paper, Land Marks for Unique Addressing( LMUA) algorithm is develped to generate unique ID for each and every node which leads to the formation of overlapping/Non overlapping clusters based on unique ID. To overcome the draw back of the developed LMUA algorithm, the concept of clustering is introduced. Based on the clustering concept a Land Marks for Unique Addressing and Clustering(LMUAC) Algorithm is developed to construct strictly non-overlapping clusters and classify those nodes in to Cluster Heads, Member Nodes, Gate way nodes and generating the Hierarchical code for the cluster heads to operate in the level one hierarchy for wireless communication switching. The expansion of the existing network can be performed or not without modifying the cost of adding the clusterhead is shown. The developed algorithm shows one way of efficiently constructing the
Abstract: Measurements of capacitance C and dissipation
factor tand of the stator insulation system provide useful information
about internal defects within the insulation. The index k is defined as
the proportionality constant between the changes at high voltage of
capacitance DC and of the dissipation factor Dtand . DC and
Dtand values were highly correlated when small flat defects were
within the insulation and that correlation was lost in the presence of
large narrow defects like electrical treeing. The discrimination
between small and large defects is made resorting to partial discharge
PD phase angle analysis. For the validation of the results, C and tand
measurements were carried out in a 15MVA 4160V steam turbine
turbogenerator placed in a sugar mill. In addition, laboratory test
results obtained by other authors were analyzed jointly. In such
laboratory tests, model coil bars subjected to thermal cycling resulted
highly degraded and DC and Dtand values were not correlated. Thus,
the index k could not be calculated.
Abstract: Microwave heating process has been developed about sixty years while measurement system has also progressed. Because of irradiation of high frequency of microwave, researchers have been utilized many costly technical instrument measuring parameters to evaluate the performance of microwave heating system. Therefore, this paper is intended to present an easier and feasible efficiency measurement method. It can help inspecting efficiency of microwave heating system with good accuracy, while the method can also give reference to optimizing procedure for microwave heating system for various load material
Abstract: The load flow study in a power system constitutes a study of paramount importance. The study reveals the electrical performance and power flows (real and reactive) for specified condition when the system is operating under steady state. This paper gives an overview of different techniques used for load flow study under different specified conditions.
Abstract: Automatic face detection is a complex problem in
image processing. Many methods exist to solve this problem such as
template matching, Fisher Linear Discriminate, Neural Networks,
SVM, and MRC. Success has been achieved with each method to
varying degrees and complexities. In proposed algorithm we used
upright, frontal faces for single gray scale images with decent
resolution and under good lighting condition. In the field of face
recognition technique the single face is matched with single face
from the training dataset. The author proposed a neural network
based face detection algorithm from the photographs as well as if any
test data appears it check from the online scanned training dataset.
Experimental result shows that the algorithm detected up to 95%
accuracy for any image.
Abstract: The adaptive power control of Code Division Multiple
Access (CDMA) communications using Remote Radio Head
(RRH) between multiple Unmanned Aerial Vehicles (UAVs) with
a link-budget based Signal-to-Interference Ratio (SIR) estimate is
applied to four inner loop power control algorithms. It is concluded
that Base Station (BS) can calculate not only UAV distance using
linearity between speed and Consecutive Transmit-Power-Control
Ratio (CTR) of Adaptive Step-size Closed Loop Power Control (ASCLPC),
Consecutive TPC Ratio Step-size Closed Loop Power Control
(CS-CLPC), Fixed Step-size Power Control (FSPC), but also UAV
position with Received Signal Strength Indicator (RSSI) ratio of
RRHs.
Abstract: The so-called all-pass filter circuits are commonly
used in the field of signal processing, control and measurement.
Being connected to capacitive loads, these circuits tend to loose their
stability; therefore the elaborate analysis of their dynamic behavior is
necessary. The compensation methods intending to increase the
stability of such circuits are discussed in this paper, including the socalled
lead-lag compensation technique being treated in detail. For
the dynamic modeling, a two-port network model of the all-pass filter
is being derived. The results of the model analysis show, that
effective lead-lag compensation can be achieved, alone by the
optimization of the circuit parameters; therefore the application of
additional electric components are not needed to fulfill the stability
requirement.
Abstract: A fully on-chip low drop-out (LDO) voltage regulator with 100pF output load capacitor is presented. A novel frequency compensation scheme using current buffer is adopted to realize single dominant pole within the unit gain frequency of the regulation loop, the phase margin (PM) is at least 50 degree under the full range of the load current, and the power supply rejection (PSR) character is improved compared with conventional Miller compensation. Besides, the differentiator provides a high speed path during the load current transient. Implemented in 0.18μm CMOS technology, the LDO voltage regulator provides 100mA load current with a stable 1.8V output voltage consuming 80μA quiescent current.
Abstract: In this paper we present a method of abrupt cut detection with a novel logic of frames- comparison. Actual frame is compared with its motion estimated prediction instead of comparison with successive frame. Four different similarity metrics were employed to estimate the resemblance of compared frames. Obtained results were evaluated by standard used measures of test accuracy and compared with existing approach. Based on the results, we claim the proposed method is more effective and Pearson correlation coefficient obtained the best results among chosen similarity metrics.
Abstract: Losses reduction initiatives in distribution systems
have been activated due to the increasing cost of supplying
electricity, the shortage in fuel with ever-increasing cost to produce
more power, and the global warming concerns. These initiatives have
been introduced to the utilities in shape of incentives and penalties.
Recently, the electricity distribution companies in Oman have been
incentivized to reduce the distribution technical and non-technical
losses with an equal annual reduction rate for 6 years. In this paper,
different techniques for losses reduction in Mazoon Electricity
Company (MZEC) are addressed. In this company, high numbers of
substation and feeders were found to be non-compliant with the
Distribution System Security Standard (DSSS). Therefore, 33
projects have been suggested to bring non-complying 29 substations
and 28 feeders to meet the planed criteria and to comply with the
DSSS. The largest part of MZEC-s network (South Batinah region)
was modeled by ETAP software package. The model has been
extended to implement the proposed projects and to examine their
effects on losses reduction. Simulation results have shown that the
implementation of these projects leads to a significant improvement
in voltage profile, and reduction in the active and the reactive power
losses. Finally, the economical analysis has revealed that the
implementation of the proposed projects in MZEC leads to an annual
saving of about US$ 5 million.
Abstract: This paper discusses coordinated reactive power -
voltage (Q-V) control in a multi machine steam power plant. The
drawbacks of manual Q-V control are briefly listed, and the design
requirements for coordinated Q-V controller are specified.
Theoretical background and mathematical model of the new
controller are presented next followed by validation of developed
Matlab/Simulink model through comparison with recorded
responses in real steam power plant and description of practical
realisation of the controller. Finally, the performance of
commissioned controller is illustrated on several examples of
coordinated Q-V control in real steam power plant and compared
with manual control.
Abstract: A novel interpolation scheme to extend usable spectrum
and upconvert in high performance D/A converters is addressed in this
paper. By adjusting the pulse width of cycle and the production circuit
of code, the expansion code is a null code or complementary code that
is interpolation process. What the times and codes of interpolation
decide DAC works in one of a normal mode or multi-mixer mode
so that convert the input digital data signal into normal signal or a
mixed analog signal having a mixer frequency that is higher than the
data frequency. Simulation results show that the novel scheme and
apparatus most extend the usable frequency spectrum into fifth to
sixth Nyquist zone beyond conventional DACs.
Abstract: This paper presents a wrap-around view system with 4
smart cameras module and remote motion mobile robot control equipped with smart camera module system. The two-level scheme for
remote motion control with smart-pad(IPAD) is introduced on this
paper. In the low-level, the wrap-around view system is controlled or operated to keep the reference points lying around top view image
plane. On the higher level, a robot image based motion controller is utilized to drive the mobile platform to reach the desired position or
track the desired motion planning through image feature feedback. The
design wrap-around view system equipped on presents such advantages as follows: 1) a satisfactory solution for the FOV and affine
problem; 2) free of any complex and constraint with robot pose. The performance of the wrap-around view equipped on mobile robot
remote control is proven by experimental results.
Abstract: In this paper, a new developed construction model of
the UPFC is proposed. The construction of this model consists of one
shunt compensation block and two series compensation blocks. In
this case, the UPFC with the new construction model will be
investigated when it is installed in multi-machine systems with nonlinear
load model. In addition, the steady–state performance of the
new model operating as impedance compensation will be presented
and compared with that obtained from the system without
compensation.