Abstract: In nature, electromagnetic fields always appear like
atmosphere static electric field, the earth's static magnetic field and
the wide-rang frequency electromagnetic field caused by lightening.
However, besides natural electromagnetic fields (EMF), today human
beings are mostly exposed to artificial electromagnetic fields due to
technology progress and outspread use of electrical devices. To
evaluate nuisance of EMF, it is necessary to know field intensity for
every frequency which appears and compare it with allowed values.
Low frequency EMF-s around transmission and distribution lines are
time-varying quasi-static electromagnetic fields which have
conservative component of low frequency electrical field caused by
charges and eddy component of low frequency magnetic field caused
by currents. Displacement current or field delay are negligible, so
energy flow in quasi-static EMF involves diffusion, analog like heat
transfer. Electrical and magnetic field can be analyzed separately.
This paper analysis the numerical calculations in ELF-400 software
of EMF in distribution substation in shopping center. Analyzing the
results it is possible to specify locations exposed to the fields and
give useful suggestion to eliminate electromagnetic effect or reduce it
on acceptable level within the non-ionizing radiation norms and
norms of protection from EMF.
Abstract: In this paper presented initial design of Low Speed
Axial Flux Permanent Magnet (AFPM) Machine with Non-Slotted
TORUS topology type by use of certain algorithm (Appendix).
Validation of design algorithm studied by means of selected data of
an initial prototype machine. Analytically design calculation carried
out by means of design algorithm and obtained results compared with
results of Finite Element Method (FEM).
Abstract: In this paper, a new alignment method based on the particle swarm optimization (PSO) technique is presented. The PSO algorithm is used for locating the optimal coupling position with the highest optical power with three-degrees of freedom alignment. This algorithm gives an interesting results without a need to go thru the complex mathematical modeling of the alignment system. The proposed algorithm is validated considering practical tests considering the alignment of two Single Mode Fibers (SMF) and the alignment of SMF and PCF fibers.
Abstract: Due to the deregulation of the Electric Supply
Industry and the resulting emergence of electricity market, the
volumes of power purchases are on the rise all over the world. In a
bid to meet the customer-s demand in a reliable and yet economic
manner, utilities purchase power from the energy market over and
above its own production. This paper aims at developing an optimal
power purchase model with two objectives viz economy and
environment ,taking various functional operating constraints such as
branch flow limits, load bus voltage magnitudes limits, unit capacity
constraints and security constraints into consideration.The price of
purchased power being an uncertain variable is modeled using fuzzy
logic. DEMO (Differential Evolution For Multi-objective
Optimization) is used to obtain the pareto-optimal solution set of the
multi-objective problem formulated. Fuzzy set theory has been
employed to extract the best compromise non-dominated solution.
The results obtained on IEEE 30 bus system are presented and
compared with that of NSGAII.
Abstract: This article presents a voltage-mode universal
biquadratic filter performing simultaneous 3 standard functions: lowpass,
high-pass and band-pass functions, employing differential
different current conveyor (DDCC) and current controlled current
conveyor (CCCII) as active element. The features of the circuit are
that: the quality factor and pole frequency can be tuned independently
via the input bias currents: the circuit description is very simple,
consisting of 1 DDCC, 2 CCCIIs, 2 electronic resistors and 2
grounded capacitors. Without requiring component matching
conditions, the proposed circuit is very appropriate to further develop
into an integrated circuit. The PSPICE simulation results are
depicted. The given results agree well with the theoretical
anticipation.
Abstract: The most important parameter in transformers life
expectancy is the hot-spot temperature level which accelerates the
rate of aging of the insulation. The aim of this paper is to present
thermal models for transformers loaded at prefabricated MV/LV
transformer substations and outdoor situations. The hot-spot
temperature of transformers is studied using their top-oil temperature
rise models. The thermal models proposed for hot-spot and top-oil
temperatures of different operating situations are compared. Since the
thermal transfer is different for indoor and outdoor transformers
considering their operating conditions, their hot-spot thermal models
differ from each other. The proposed thermal models are verified by
the results obtained from the experiments carried out on a typical
1600 kVA, 30 /0.4 kV, ONAN transformer for both indoor and
outdoor situations.