Abstract: Paper mill sludge is one of the major economic and environmental problems for paper and board industry, million tonnes quantity of sludge is produced in the world. It is essential to dispose these wastes safely without affecting health of human being, environment, fertile land; sources of water bodies, economy as it adversely affect the strength, durability and other properties of building materials based on them. Moreover, in developing countries like India where there is low availability of non-renewable resources and large need of building material like cement therefore it is essential to develop eco-efficient utilization of paper sludge. Primarily in functional terms paper sludge comprises of cellulose fibers, calcium carbonate, china clay, low silica, residual chemical bonds with water. The material is sticky and full of moisture content which is hard to dry. The manufacturing of paper usually produce loads of solid waste. These paper fibers are recycled in paper mills to limited number of times till they become weak to produce high quality paper. Thereafter, these left out small and weak pieces called as low quality paper fibers are detached out to become paper sludge. The material is by-product of de-inking and re-pulping of paper. This hypo sludge includes all kinds of inks, dyes, coating etc inscribed on the paper. This paper presents an overview of the published work on the use of hypo sludge in M25 concrete formulations as a supplementary cementitious material exploring its properties such as compressive strength, splitting and parameters like modulus of elasticity, density, applications and most importantly investigation of low cost concrete by using hypo sludge are presented.
Abstract: Self-compacting concrete (SCC) developed in Japan
in the late 80s has enabled the construction industry to reduce
demand on the resources, improve the work condition and also
reduce the impact of environment by elimination of the need for
compaction. Fuzzy logic (FL) approaches has recently been used to
model some of the human activities in many areas of civil
engineering applications. Especially from these systems in the model
experimental studies, very good results have been obtained. In the
present study, a model for predicting compressive strength of SCC
containing various proportions of fly ash, as partial replacement of
cement has been developed by using Fuzzy Inference System (FIS).
For the purpose of building this model, a database of experimental
data were gathered from the literature and used for training and
testing the model. The used data as the inputs of fuzzy logic models
are arranged in a format of five parameters that cover the total binder
content, fly ash replacement percentage, water content,
superplasticizer and age of specimens. The training and testing results
in the fuzzy logic model have shown a strong potential for predicting
the compressive strength of SCC containing fly ash in the considered
range.
Abstract: The paper presents a plastic analysis procedure based
on the energy balance concept for performance based seismic retrofit
of multi-story multi-bay masonry infilled reinforced concrete (R/C)
frames with a ‘soft’ ground story using passive energy dissipation
(PED) devices with the objective of achieving a target performance
level of the retrofitted R/C frame for a given seismic hazard level at
the building site. The proposed energy based plastic analysis
procedure was employed for developing performance based design
(PBD) formulations for PED devices for a simulated application in
seismic retrofit of existing frame structures designed in compliance
with the prevalent standard codes of practice. The PBD formulations
developed for PED devices were implemented for simulated seismic
retrofit of a representative code-compliant masonry infilled R/C
frame with a ‘soft’ ground story using friction dampers as the PED
device. Non-linear dynamic analyses of the retrofitted masonry
infilled R/C frames is performed to investigate the efficacy and
accuracy of the proposed energy based plastic analysis procedure in
achieving the target performance level under design level
earthquakes. Results of non-linear dynamic analyses demonstrate that
the maximum inter-story drifts in the masonry infilled R/C frames
with a ‘soft’ ground story that is retrofitted with the friction dampers
designed using the proposed PBD formulations are controlled within
the target drifts under near-field as well far-field earthquakes.
Abstract: Currently, seismic probabilistic risk assessments
(SPRA) for nuclear facilities use In-Structure Response Spectra
(ISRS) in the calculation of fragilities for systems and components.
ISRS are calculated via dynamic analyses of the host building
subjected to two orthogonal components of horizontal ground
motion. Each component is defined as the median motion in any
horizontal direction. Structural engineers applied the components
along selected X and Y Cartesian axes. The ISRS at different
locations in the building are also calculated in the X and Y directions.
The choice of the directions of X and Y are not specified by the
ground motion model with respect to geographic coordinates, and are
rather arbitrarily selected by the structural engineer. Normally, X and
Y coincide with the “principal” axes of the building, in the
understanding that this practice is generally conservative. For SPRA
purposes, however, it is desirable to remove any conservatism in the
estimates of median ISRS. This paper examines the effects of the
direction of horizontal seismic motion on the ISRS on typical nuclear
structure. We also evaluate the variability of ISRS calculated along
different horizontal directions. Our results indicate that some central
measures of the ISRS provide robust estimates that are practically
independent of the selection of the directions of the horizontal
Cartesian axes.
Abstract: Precast residential houses are normally constructed in Malaysia using precast shear-key wall panel and this panel is designed using BS8110 where there is no provision for earthquake. However, the safety of this house under moderate and strong earthquake is still questionable. Consequently, the full-scale of residential house are designed, constructed, tested and analyzed under in-plane lateral quasi-static cyclic loading. Hysteresis loops are plotted based on the experimental work and compared with modeling of hysteresis loops using HYSTERES in RUAUMOKO 2D program. Modified Takeda hysteresis model is chosen to behave a similar pattern with experimental work. This program will display the earthquake excitations, spectral displacements, pseudo spectral acceleration, mode shape and deformation of the structure. It can be concluded that this building is suffering severe cracks and damage under moderate and severe earthquake.
Abstract: In this paper, the influence of upstream structures on the flow patternaround and inside the wind-catcher is experimentally investigated by smoke flow visualization techniques. Wind-catchers are an important part of natural ventilation in residential buildings or public places such as shopping centers, libraries, etc. Wind-catchers might be also used in places of high urban densities; hence their potential to provide natural ventilation is dependent on the presence of upstream structures. In this study, the two-sided wind-catcher model was based on a real wind-catcher observed in the city of Yazd, Iran. The present study focuses on the flow patterns around and inside the isolated two-sided wind-catcher, and on a two-sided wind-catcher in the presence of an upstream structure. The results show that the presence of an upstream structure influences the airflow pattern force and direction. Placing a high upstream structure reverses the airflow direction inside the wind-catcher.
Abstract: This work is focused on the study of valuation of
recycled concrete aggregates, by measuring certain properties of
concrete in the fresh and hardened state. In this study, rheological
tests and physic-mechanical characterization on concretes and
mortars were conducted with recycled concrete whose geometric
properties were identified aggregates. Mortars were elaborated with
recycled fine aggregate (0/5mm) and concretes were manufactured
using recycled coarse aggregates (5/12.5 mm and 12.5/20 mm). First,
a study of the mortars was conducted to determine the effectiveness
of polycarboxylate superplasticizer on the workability of these and
their action deflocculating of the recycled sand. The rheological
behavior of mortars based on fine aggregate recycled was
characterized. The results confirm that the mortars composed of
different fractions of recycled sand (0 /5) have a better mechanical
properties (compressive and flexural strength) compared to normal
mortar. Also, the mechanical strengths of concretes made with
recycled aggregates (5/12.5 mm and 12.5/20 mm), are comparable to
those of conventional concrete with conventional aggregates,
provided that the implementation can be improved by the addition of
a superplasticizer.
Abstract: Asphaltic concrete for pavement construction in India
are produced by using crushed stone, gravels etc. as aggregate. In
north-Eastern region of India, there is a scarcity of stone aggregate.
Therefore the road engineers are always in search of an optional
material as aggregate which can replace the regularly used material.
The purpose of this work was to evaluate the utilization of
substandard or marginal aggregates in flexible pavement
construction. The investigation was undertaken to evaluate the effects
of using lower quality aggregates such as over burnt brick aggregate
on the preparation of asphalt concrete for flexible pavements. The
scope of this work included a review of available literature and
existing data, a laboratory evaluation organized to determine the
effects of marginal aggregates and potential techniques to upgrade
these substandard materials, and a laboratory evaluation of these
upgraded marginal aggregate asphalt mixtures. Over burnt brick
aggregates are water susceptible and can leads to moisture damage.
Moisture damage is the progressive loss of functionality of the
material owing to loss of the adhesion bond between the asphalt
binder and the aggregate surface. Hence zycosoil as an anti striping
additive were evaluated in this study. This study summarizes the
results of the laboratory evaluation carried out to investigate the
properties of asphalt concrete prepared with zycosoil modified over
burnt brick aggregate. Marshall specimen were prepared with stone
aggregate, zycosoil modified stone aggregate, over burnt brick
aggregate and zycosoil modified over burnt brick aggregate. Results
show that addition of zycosoil with stone aggregate increased
stability by 6% and addition of zycosoil with over burnt brick
aggregate increased stability by 30%.
Abstract: This paper evaluates the performance of a multi-lane
four legged modern roundabout operating in Muscat using SIDRA
model. The performance measures include Degree of Saturation
(DOS), average delay, and queue lengths. The geometric and traffic
data were used for model preparation. Gap acceptance parameters,
critical gap and follow up headway, were used for calibration of
SIDRA model. The results from the analysis showed that currently
the roundabout is experiencing delays up to 610 seconds per vehicle
with DOS 1.67 during peak hour. Further, sensitivity analysis for
general and roundabout parameters was performed, amongst lane
width, cruise speed, inscribed diameter, entry radius and entry angle
showed that inscribed diameter is most crucial factor affecting delay
and DOS. Up gradation of roundabout to fully signalized junction
was found as the suitable solution which will serve for future years
with LOS C for design year having DOS of 0.9 with average control
delay of 51.9 seconds per vehicle.
Abstract: Series of laboratory tests were carried out to study the
extent of scour caused by a three-dimensional wall jets exiting from a
square cross-section nozzle and into a non-cohesive sand beds.
Previous observations have indicated that the effect of the tail water
depth was significant for densimetric Froude number greater than ten.
However, the present results indicate that the cut off value could be
lower depending on the value of grain size-to-nozzle width ratio.
Numbers of equations are drawn out for a better scaling of numerous
scour parameters. Also suggested the empirical prediction of scour to
predict the scour centre line profile and plan view of scour profile at
any particular time.
Abstract: The main objective of the study is focused in
producing slag based geopolymer concrete obtained with the addition
of alkali activator. Test results indicated that the reaction of silicates
in slag is based on the reaction potential of sodium hydroxide and the
formation of alumino-silicates. The study also comprises on the
evaluation of the efficiency of polymer reaction in terms of the
strength gain properties for different geopolymer mixtures.
Geopolymer mixture proportions were designed for different binder
to total aggregate ratio (0.3 & 0.45) and fine to coarse aggregate ratio
(0.4 & 0.8). Geopolymer concrete specimens casted with normal
curing conditions reported a maximum 28 days compressive strength
of 54.75 MPa. The addition of glued steel fibres at 1.0% Vf in
geopolymer concrete showed reasonable improvements on the
compressive strength, split tensile strength and flexural properties of
different geopolymer mixtures. Further, comparative assessment was
made for different geopolymer mixtures and the reinforcing effects of
steel fibres were investigated in different concrete matrix.
Abstract: Climate change would cause mean sea level to rise +1
m by 2100. To prevent coastal floods resulting from the sea level
rising, different flood control structures have been built, with
acceptable protection levels. Gothenburg with the River Göta älv
located on the southwest coast of Sweden is a vulnerable city to the
accelerated rises in mean sea level. We evaluated using a sea barrage
in the River Göta älv to protect Gothenburg during this century. The
highest sea level was estimated to 2.95 m above the current mean sea
level by 2100. To verify flood protection against such high sea levels,
both barriers have to be closed. To prevent high water level in the
River Göta älv reservoir, the barriers would be open when the sea
level is low. The suggested flood control structures would
successfully protect the city from flooding events during this century.
Abstract: Using ETABS software, this study analyzed 23
buildings to evaluate effects of mistakes during construction phase on
buildings structural behavior. For modelling, two different loadings
were assumed: 1) design loading and 2) loading due to the effects of
mistakes in construction phase. Research results determined that
considering traditional construction methods for buildings resulted in
a significant increase in dead loads and consequently intensified the
displacements and base-shears of buildings under seismic loads.
Abstract: South Africa has some regions which are susceptible
to moderate seismic activity. A peak ground acceleration of between
0.1g and 0.15g can be expected in the southern parts of the Western
Cape. Unreinforced Masonry (URM) is commonly used as a
construction material for 2 to 5 storey buildings in underprivileged
areas in and around Cape Town. URM is typically regarded as the
material most vulnerable to damage when subjected to earthquake
excitation. In this study, a three-storey URM building was analysed
by applying seven earthquake time-histories, which can be expected
to occur in South Africa using a finite element approach.
Experimental data was used to calibrate the in- and out-of-plane
stiffness of the URM. The results indicated that tensile cracking of
the in-plane piers was the dominant failure mode. It is concluded that
URM buildings of this type are at risk of failure especially if
sufficient ductility is not provided. The results also showed that
connection failure must be investigated further.
Abstract: Columns have traditionally been constructed of
reinforced concrete or structural steel. Much attention was allocated
to estimate the axial capacity of the traditional column sections to the
detriment of other forms of construction. Other forms of column
construction such as Concrete Filled Double Skin Tubes received
little research attention, and almost no attention when subjected to
eccentric loading. This paper investigates the axial capacity of
columns when subjected to eccentric loading. The experimental axial
capacities are compared to other established theoretical formulae on
concentric loading to determine a possible relationship. The study
found a good correlation between the reduction in axial capacity for
different column lengths and hollow section ratios.
Abstract: Pavement surface unevenness plays a pivotal role on
roughness index of road which affects on riding comfort ability.
Comfort ability refers to the degree of protection offered to vehicle
occupants from uneven elements in the road surface. So, it is
preferable to have a lower roughness index value for a better riding
quality of road users. Roughness is generally defined as an
expression of irregularities in the pavement surface which can be
measured using different equipments like MERLIN, Bump integrator,
Profilometer etc. Among them Bump Integrator is quite simple and
less time consuming in case of long road sections. A case study is
conducted on low volume roads in West District in Tripura to
determine roughness index (RI) using Bump Integrator at the
standard speed of 32 km/h. But it becomes too tough to maintain the
requisite standard speed throughout the road section. The speed of
Bump Integrator (BI) has to lower or higher in some distinctive
situations. So, it becomes necessary to convert these roughness index
values of other speeds to the standard speed of 32 km/h. This paper
highlights on that roughness index conversional model. Using SPSS
(Statistical Package of Social Sciences) software a generalized
equation is derived among the RI value at standard speed of 32 km/h
and RI value at other speed conditions.
Abstract: Paper presents a study about dynamic effects obtained
from the dynamic load testing of the city highway bridges in Latvia
carried out from 2005 to 2012. 9 prestressed concrete bridges and 4
composite bridges were considered. 11 of 13 bridges were designed
according to the Eurocodes but two according to the previous
structural codes used in Latvia (SNIP 2.05.03-84). The dynamic
properties of the bridges were obtained by heavy vehicle passing the
bridge roadway with different driving speeds and with or without
even pavement. The obtained values of the Dynamic amplification
factor (DAF) and the bridge natural frequency were analyzed and
compared to the values of built-in traffic load models provided in
Eurocode 1. The actual DAF values for even bridge pavement in the
most cases are smaller than the value adopted in Eurocode 1. Vehicle
speed for uneven pavements significantly influence Dynamic
amplification factor values.
Abstract: The thermo-mechanical behaviour of concrete energy
pile foundations with different single and double U-tube shapes
incorporated was analysed using the Comsol Multi-physics package.
For the analysis, a 3D numerical model in real scale of the concrete
pile and surrounding soil was simulated regarding actual operation of
ground heat exchangers (GHE) and the surrounding ambient
temperature. Based on initial ground temperature profile measured in
situ, tube inlet temperature was considered to range from 6oC to 0oC
(during the contraction process) over a 30-day period. Extra thermal
stresses and deformations were calculated during the simulations and
differences arising from the use of two different systems (single-tube
and double-tube) were analysed. The results revealed no significant
difference for extra thermal stresses at the centre of the pile in either
system. However, displacements over the pile length were found to
be up to 1.5-fold higher in the double-tube system than the singletube
system.
Abstract: This paper present the experimental work of double
unit tunnel form building (TFB) subjected to in-plane lateral cyclic
loading. A one third scale of 3-storey double unit of TFB is tested
until its strength degradation. Then, the TFB is repaired and
retrofitted using additional shear wall, steel angle and CFRP sheet.
The crack patterns, lateral strength, stiffness, ductility and equivalent
viscous damping (EVD) were analyzed and compared before and
after repair and retrofit. The result indicates that the lateral strength
increases by 22% in pushing and 27% in pulling direction. Moreover,
the stiffness and ductility obtained before and after retrofit increase
tremendously by 87.87% and 39.66%, respectively. Meanwhile, the
energy absorption measured by equivalent viscous damping obtained
after retrofit increase by 12.34% in pulling direction. It can be
concluded that the proposed retrofit method is capable to increase the
lateral strength capacity, stiffness and energy absorption of double
unit TFB.
Abstract: Supermarkets are the most electricity-intensive type of
commercial buildings. The unsuitable indoor environment of a
supermarket provided by abnormal HVAC operations incurs waste
energy consumption in refrigeration systems. This current study
briefly describes significantly solid backgrounds and proposes easyto-
use analysis terminology for investigating the impact of HVAC
operations on refrigeration power consumption using the field-test
data obtained from building automation system (BAS). With solid
backgrounds and prior knowledge, expected energy interactions
between HVAC and refrigeration systems are proposed through
Pearson’s correlation analysis (R value) by considering correlations
between equipment power consumption and dominantly independent
variables (driving force conditions).The R value can be conveniently
utilized to evaluate how strong relations between equipment
operations and driving force parameters are. The calculated R values
obtained from field data are compared to expected ranges of R values
computed by energy interaction methodology. The comparisons can
separate the operational conditions of equipment into faulty and
normal conditions. This analysis can simply investigate the condition
of equipment operations or building sensors because equipment could
be abnormal conditions due to routine operations or faulty
commissioning processes in field tests. With systematically solid and
easy-to-use backgrounds of interactions provided in the present
article, the procedures can be utilized as a tool to evaluate the proper
commissioning and routine operations of HVAC and refrigeration
systems to detect simple faults (e.g. sensors and driving force
environment of refrigeration systems and equipment set-point) and
optimize power consumption in supermarket buildings. Moreover,
the analysis will be used to further study the FDD research for
supermarkets in future.