Abstract: Heavy metal transfer in soil profiles is a major
environmental concern because even slow transport through the soil
may eventually lead to deterioration of groundwater quality. The use
of sewage sludge and effluents from wastewater treatment plants for
irrigation of agricultural lands is on the rise particularly in peri-urban
area of developing countries. In this study soil samples under sludge
application and wastewater irrigation were studied and soil samples
were collected in the soil profiles from the surface to 100 cm in
depth. For this purpose, three plots were made in a treatment plant in
south of Tehran-Iran. First plot was irrigated just with effluent from
wastewater treatment plant, second plot with simulated heavy metals
concentration equal 50 years irrigation and in third plot sewage
sludge and effluent was used. Trace metals concentration (Cd, Cu)
were determined for soil samples. The results indicate movement of
metals was observed, but the most concentration of metals was found
in topsoil samples. The most of Cadmium concentration was
measured in the topsoil of plot 3, 4.5mg/kg and Maximum cadmium
movement was observed in 0-20 cm. The most concentration of
copper was 27.76mg/kg, and maximum percolation in 0-20 cm.
Metals (Cd, Cu) were measured in leached water. Preferential flow
and metal complexation with soluble organic apparently allow
leaching of heavy metals.
Abstract: This paper has examined the energy consumption characteristics in six different buildings including apartments, offices, commercial buildings, hospitals, hotels and educational facilities. Then 5-hectare (50000m2) development site for respective building-s type has been assumed as case study to evaluate the introduction effect of Combined Heat and Power (CHP). All kinds of CHP systems with different distributed generation technologies including Gas Turbine (GT), Gas Engine (GE), Diesel Engine (DE), Solid Oxide Fuel Cell (SOFC) and Polymer Electrolyte Fuel Cell (PEFC), have been simulated by using HEATMAP, CHP system analysis software. And their primary energy utilization efficiency, energy saving ratio and CO2 reduction ratio have evaluated and compared respectively. The results can be summarized as follows: Various buildings have their special heat to power ratio characteristics. Matching the heat to power ratio demanded from an individual building with that supplied from a CHP system is very important. It is necessary to select a reasonable distributed generation technologies according to the load characteristics of various buildings. Distributed generation technologies with high energy generating efficiency and low heat to power ratio, like SOFC and PEFC is more reasonable selection for Building Combined Heat and Power (BCHP). CHP system is an attractive option for hotels, hospitals and apartments in Japan. The users can achieve high energy saving and environmental benefit by introducing a CHP systems. In others buildings, especially like commercial buildings and offices, the introduction of CHP system is unreasonable.
Abstract: To make use of the limited amounts of water in arid
region, the Iranians developed man-made underground water
channels called qanats (kanats) .In fact, qanats may be considered as
the first long-distance water transfer system. Qanats are an ancient
water transfer system found in arid regions wherein groundwater
from mountainous areas, aquifers and sometimes from rivers, was
brought to points of re-emergence such as an oasis, through one or
more underground tunnels. The tunnels, many of which were
kilometers in length, had designed for slopes to provide gravitational
flow. The tunnels allowed water to drain out to the surface by gravity
to supply water to lower and flatter agricultural land.
Qanats have been an ancient, sustainable system facilitating the
harvesting of water for centuries in Iran, and more than 35 additional
countries of the world such as India, Arabia, Egypt, North Africa,
Spain and even to New world.
There are about 22000 qanats in Iran with 274000 kilometers of
underground conduits all built by manual labor. The amount of
water of the usable qanats of Iran produce is altogether 750 to
1000 cubic meter per second. The longest chain of qanat is
situated in Gonabad region in Khorasan province. It is 70
kilometers long. Qanats are renewable water supply systems that
have sustained agricultural settlement on the Iranian plateau for
millennia. The great advantages of Qanats are no evaporation
during transit, little seepage , no raising of the water- table and no
pollution in the area surrounding the conduits. Qanat systems
have a profound influence on the lives of the water users in Iran, and
conform to Iran-s climate. Qanat allows those living in a desert
environment adjacent to a mountain watershed to create a large oasis
in an otherwise stark environment.
This paper explains qanats structure designs, their history,
objectives causing their creation, construction materials, locations
and their importance in different times, as well as their present
sustainable role in Iran.
Abstract: A direct search approach to determine optimal reservoir operating is proposed with ant colony optimization for continuous domains (ACOR). The model is applied to a system of single reservoir to determine the optimum releases during 42 years of monthly steps. A disadvantage of ant colony based methods and the ACOR in particular, refers to great amount of computer run time consumption. In this study a highly effective procedure for decreasing run time has been developed. The results are compared to those of a GA based model.
Abstract: Dust storms are one of the most costly and destructive
events in many desert regions. They can cause massive damages both
in natural environments and human lives. This paper is aimed at
presenting a preliminary study on dust storms, as a major natural
hazard in arid and semi-arid regions. As a case study, dust storm
events occurred in Zabol city located in Sistan Region of Iran was
analyzed to diagnose and predict dust storms. The identification and
prediction of dust storm events could have significant impacts on
damages reduction. Present models for this purpose are complicated
and not appropriate for many areas with poor-data environments. The
present study explores Gamma test for identifying inputs of ANNs
model, for dust storm prediction. Results indicate that more attempts
must be carried out concerning dust storms identification and
segregate between various dust storm types.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: Cement stabilization has been widely used for
improving the strength and stiffness of soft clayey soils. Cement
treated soil specimens used to investigate the stress-strain behaviour in
the laboratory study are usually cured for 7 days. This paper examines
the effects of curing time on the strength and stress strain behaviour of
cement treated marine clay under triaxial loading condition.
Laboratory-prepared cement treated Singapore marine clay with
different mix proportion S-C-W (soil solid-cement solid-water) and
curing time (7 days to 180 days) was investigated through conducting
unconfined compressive strength test and triaxial test. The results
show that the curing time has a significant effect on the unconfined
compressive strength u q , isotropic compression behaviour and stress
strain behaviour. Although the primary yield loci of the cement treated
soil specimens with the same mix proportion expand with curing time,
they are very narrowly banded and have nearly the same shape after
being normalized by isotropic compression primary stress '
py p . The
isotropic compression primary yield stress '
py p was shown to be
linearly related to unconfined compressive strength u q for specimens
with different curing time and mix proportion. The effect of curing
time on the hardening behaviour will diminish with consolidation
stress higher than isotropic compression primary yield stress but its
damping rate is dependent on the cement content.