Abstract: During the process of compaction in Hot-Mix Asphalt
(HMA) mixtures, the distance between aggregate particles decreases
as they come together and eliminate air-voids. By measuring the
inter-particle distances in a cut-section of a HMA sample the degree
of compaction can be estimated. For this, a calibration curve is
generated by computer simulation technique when the gradation and
asphalt content of the HMA mixture are known. A two-dimensional
cross section of HMA specimen was simulated using the mixture
design information (gradation, asphalt content and air-void content).
Nearest neighbor distance methods such as Delaunay triangulation
were used to study the changes in inter-particle distance and area
distribution during the process of compaction in HMA. Such
computer simulations would enable making several hundreds of
repetitions in a short period of time without the necessity to compact
and analyze laboratory specimens in order to obtain good statistics on
the parameters defined. The distributions for the statistical
parameters based on computer simulations showed similar trends as
those of laboratory specimens.
Abstract: There has been a growing interest in the oxygenation
by plunging water jets in the last few years due to their inherent
advantages, like energy-efficient, low operation cost, etc. Though a
lot of work has been reported on the oxygen-transfer by single
plunging water jets but very few studies have been carried out using
multiple plunging jets. In this paper, volumetric oxygen-transfer
coefficient and oxygen-transfer efficiency has been studied
experimentally for multiple inclined plunging jets (having jet plunge
angle of 60 0 ) in a pool of water for different configurations, in
terms of varying number of jets and jet diameters. This research
suggests that the volumetric oxygen-transfer coefficient and oxygentransfer
efficiency of the multiple inclined plunging jets for air-water
system are significantly higher than those of a single vertical as well
as inclined plunging jet for same flow area and other similar
conditions. The study also reveals that the oxygen-transfer increase
with increase in number of multiple jets under similar conditions,
which will be most advantageous and energy-efficient in practical
situations when large volumes of wastewaters are to be treated. A
relationship between volumetric oxygen-transfer coefficient and jet
parameters is also proposed. The suggested relationship predicts the
volumetric oxygen-transfer coefficient for multiple inclined plunging
jet(s) within a scatter of ±15 percent. The relationship will be quite
useful in scale-up and in deciding optimum configuration of multiple
inclined plunging jet aeration system.
Abstract: Design of Converter transformer insulation is a major
challenge. The insulation of these transformers is stressed by both
AC and DC voltages. Particle contamination is one of the major
problems in insulation structures, as they generate partial discharges
leading it to major failure of insulation. Similarly corona discharges
occur in transformer insulation. This partial discharge due to particle
movement / corona formation in insulation structure under different
voltage wave shapes, are different. In the present study, UHF
technique is adopted to understand the discharge activity and could
be realized that the characteristics of UHF signal generated under
low and high fields are different. In the case of corona generated
signal, the frequency content of the UHF sensor output lies in the
range 0.3-1.2 GHz and is not much varied except for its increase in
magnitude of discharge with the increase in applied voltage. It is
realized that the current signal injected due to partial
discharges/corona is about 4ns duration measured for first one half
cycle. Wavelet technique is adopted in the present study. It allows
one to identify the frequency content present in the signal at different
instant of time. The STD-MRA analysis helps one to identify the
frequency band in which the energy content of the UHF signal is
maximum.