Transient Stability Improvement in Multi-Machine System Using Power System Stabilizer (PSS) and Static Var Compensator (SVC)

Increasingly complex modern power systems require stability, especially for transient and small disturbances. Transient stability plays a major role in stability during fault and large disturbance. This paper compares a power system stabilizer (PSS) and static Var compensator (SVC) to improve damping oscillation and enhance transient stability. The effectiveness of a PSS connected to the exciter and/or governor in damping electromechanical oscillations of isolated synchronous generator was tested. The SVC device is a member of the shunt FACTS (flexible alternating current transmission system) family, utilized in power transmission systems. The designed model was tested with a multi-machine system consisting of four machines six bus, using MATLAB/SIMULINK software. The results obtained indicate that SVC solutions are better than PSS.




References:
[1] G. Hingorani and L. Gyugyi, “Understanding FACTS, Concepts, and
Technology of Flexible AC Transmission Systems”, Piscataway, NJ:
IEEE Press, 2000.
[2] A. A Edris, R Aapa, M H Baker, L Bohman, K Clark, “Proposed terms
and definitions for flexible ac transmission system (FACTS)”, IEEE
Trans. on Power Delivery, Vol. 12, No. 4, 1997, pp. 1848-1853.
[3] P. Kundur, Power System Stability and Control, New York: McGraw
Hill, 1994.
[4] Dash. P. K, Selta Morris and Mishra. S, “Design of a nonlinear Variable
Controller for FACTS Devices”, IEEE Transactions on Control System
Technology, Vol. 12. No. 3, May 2004.
[5] Patel, H. D,Majmudar, C,―Fuzzy logic application to single machine
power system stabilizer,‖ Power Nirma University International
Conference on Engineering, IEEE, Vol. 2, pp. 669- 674, Dec 2011.
[6] M. A. Abido, “ Analysis and assessment of STATCOM based damping
stabilizers for Power system stability enhancement” Electric Power
System Research,73, 177- 185,2005
[7] Mohan Mathur, Rajiv K. Varma , ―Thyristor-Based Facts Controllers
for Electrical Transmission Systems, John Wiley &Sons, Inc.
Publication, 2002, pp 93-138.
[8] B T Ooi, M Kazerrani, R Marcean, Z Wolanski, F D Galiana, D.
Megillis, G. Joos, “Midpoint sitting of FACTS devices in transmission
lines”, IEEE Tran. On Power Delivery, Vol. 1 No. 4, 1997, pp. 1717-
1722.
[9] S. M. Barakati, S. Khanmohamadi, S. H. Hosseini, “Improving the
Power Stability using Fuzzy Logic Controlled Static Var Compensator”,
The 4th Iranian Conference on Electrical Engineering, ICEE-97, 1996.
[10] Mitsubishi Electric. (2010). Power system stabilizer PSS
[11] Samuelsson, O. (1997). Power system damping-structural aspects of
controlling active power. Lund University.
[12] Liu, F. , Yokoyama, R. , Zhou, Y. , & Wu, M. Study on Oscillation
Damping Effects of Power System Stabilizer with Eigenvalue Analysis
Method for the Stability of Power Systems.
[13] E. Z. Zhou, ―Application of Static Var Compensators to Increase
Power System Damping, IEEE Transactions on Power Systems, Vol. 8,
NO. 2, 1993.
[14] M. H. Hague, ―Improvement of first stability limit by utilizing full
benefit of shunt FACTS devices, IEEE Transactions On Power Systems,
vol. 19, no. 4, pp. 1894 – 1902, 2004.
[15] Arunkumar, Priya G, ―Power System Stability Enhancement using
FACTS Controllers,‖ IEEE, 2012.
[16] Claudio A. canizares, ―Power Flow and Transient Stability Models of
FACTS Controllers for Voltage and angle Stability Studies, IEEE PES,
2000.