Simulation and Analysis of Polyetheretherketone Implants for Diaphysis Femur Fracture

In the present work, reverse engineering approach has been used to create a 3D model of a fractured femur diaphysis bone using the computed tomography (CT) scan data. Thereafter, a counter fit fixation plate of polyetheretherketone (PEEK) composite has been designed and analyzed considering static physiological loading conditions. Static stress distribution and deformation analysis of the plate have been performed. From the analysis, it has been found that the stresses and deformation developed are quite low. This implies that these designed fixation plates will be able to provide stable fixation and thus resulting in improved fracture union.





References:
[1] W. M. Ricci, B. Gallagher, G. J. Haidukewych, “Intramedullary nailing of femoral shaft fractures: current concepts,” Journal of the American Academy of Orthopaedic Surgeons, vol. 17, no. 5, pp. 296–305, 2009.
[2] M. Malik, P. Harwood, P. Diggle and S. A. Khan S.A., “Factors affecting rates of infection and nonunion in intramedullary nailing,” The Journal of bone and joint surgery, British Volume, vol. 86, no. 4, pp. 556–560, 2004.
[3] P. R. Wolinsky, E. McCarty, Y. Shyr and K. Johnson, “Reamed intramedullary nailing of the femur: 551 cases,” Journal of Trauma and Acute Care Surgery, vo. 46, no. 3, pp. 392–399, 1999.
[4] A. Gefen, “Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation,” Medical Engineering & Physics, vol. 24, no. 5, pp. 337–347, 2002.
[5] C. G. Finkemeier and M. W. Chapman, “Treatment of femoral diaphyseal nonunions,” Clinical Orthopaedics and Related Research, vol. 398, pp. 223–234, 2002.
[6] A. Marro, T. Bandukwala and W. Mak, “Three-dimensional printing and medical imaging: a review of the methods and applications,” Current Problems in Diagnostic Radiology, vol. 45, no. 1, pp. 2–9, 2016.
[7] Y. P. Lin, C. T. Wang and K. R. Dai, “Reverse engineering in CAD model reconstruction of customized artificial joint,” Medical Engineering & Physics, vol. 27, no. 2, pp. 89–193, 2005.
[8] S. P. George and G. Saravana, “Patient specific parametric geometric modelling and finite element analysis of cementless hip prosthesis: This paper proposes a framework for subject-specific cementless hip implant design and virtual assembly analysis of the instantiated stem with femur,” Virtual and Physical Prototyping, vol. 8, no. 1, pp. 65–83, 2013.
[9] D. J. Thomas, M. Azmi and Z. Tehrani, “3D additive manufacture of oral and maxillofacial surgical models for preoperative planning,” International Journal of Advanced Manufacturing Technology, vol. 71, pp. 1643–1651, 2014.
[10] D. S. Shin, K. Lee and D. Kim, “Biomechanical study of lumbar spine with dynamic stabilization device using finite element method,” Computer-Aided Design, vol. 39, no. 7, pp. 559–567, 2007.