Semi-Analytic Method in Fast Evaluation of Thermal Management Solution in Energy Storage System

This article presents the application of the semi-analytic method (SAM) in the thermal management solution (TMS) of the energy storage system (ESS). The TMS studied in this work is fluid cooling. In fluid cooling, both effective heat conduction and heat convection are indispensable due to the heat transfer from solid to fluid. Correspondingly, an efficient TMS requires a design investigation of the following parameters: fluid inlet temperature, ESS initial temperature, fluid flow rate, working c rate, continuous working time, and materials properties. Their variation induces a change of thermal performance in the battery module, which is usually evaluated by numerical simulation. Compared to complicated computation resources and long computation time in simulation, the SAM is developed in this article to predict the thermal influence within a few seconds. In SAM, a fast prediction model is reckoned by combining numerical simulation with theoretical/empirical equations. The SAM can explore the thermal effect of boundary parameters in both steady-state and transient heat transfer scenarios within a short time. Therefore, the SAM developed in this work can simplify the design cycle of TMS and inspire more possibilities in TMS design.

Authors:



References:
[1] https://www.renewable-ei.org/en/statistics/international/.
[2] Dr. V. Gomathy, Dr.S. Sheeba Rani, Dr.K. Sujatha. Soft switched solar integrated power optimizer, International Journal of Pure and Applied Mathematics, Volume 119 No. 12 2018, 1655-1663.
[3] Shuai Ma, Modi Jiang, Peng Tao, Chengyi Song, Jianbo Wu, Jun Wang, Tao Deng, Wen Shang. Temperature effect and thermal impact in lithium-ion batteries: A review, Progress in Natural Science: Materials International Volume 28, Issue 6, December 2018, Pages 653-666.
[4] U. Iraola, I. Aizpuru, J. M. Canales, A. Etxeberria and I. Gil. "Methodology for thermal modelling of lithium-ion batteries," IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society, Vienna, 2013, pp. 6752-6757, doi: 10.1109/IECON.2013.6700250.
[5] https://www.thermal-engineering.org/what-is-laminar-vs-turbulent-nusselt-number-definition/.
[6] Arun Mambazhasseri Divakaran, Dean Hamilton, Krishna Nama Manjunatha and Manickam Minakshi. Design, Development and Thermal Analysis of Reusable Li-Ion Battery Module for Future Mobile and Stationary Applications. Energies 2020, 13, 1477.
[7] Chengtao Lin, Can Cui, Xiaotian Xu. Lithium-ion Battery Electro-thermal Model and Its Application in the Numerical Simulation of Short Circuit Experiment. EVS27 Barcelona, Spain, November 17-20, 2013.