Research on the Impact on Building Temperature and Ventilation by Outdoor Shading Devices in Hot-Humid Area: Through Measurement and Simulation on an Office Building in Guangzhou

Shading devices (SDs) are widely used in buildings in the hot-humid climate areas for reducing cooling energy consumption for interior temperature, as the result of reducing the solar radiation directly. Contrasting the surface temperature of materials of SDs to the glass on the building façade could give more analysis for the shading effect. On the other side, SDs are much more used as the independence system on building façade in hot-humid area. This typical construction could have some impacts on building ventilation as well. This paper discusses the outdoor SDs’ effects on the building thermal environment and ventilation, through a set of measurements on a 2-floors office building in Guangzhou, China, which install a dynamic aluminum SD-system around the façade on 2nd-floor. The measurements recorded the in/outdoor temperature, relative humidity, velocity, and the surface temperature of the aluminum panel and the glaze. After that, a CFD simulation was conducted for deeper discussion of ventilation. In conclusion, this paper reveals the temperature differences on the different material of the façade, and finds that the velocity of indoor environment could be reduced by the outdoor SDs.





References:
[1] Florides, GA, Kalogirou, SA. Modeling of the modern houses of Cyprus and energy consumption analysis; 2000. 25:915–37.
[2] HS, Ã, Binder, B. Experimental and numerical determination of the total solar energy transmittance of glazing with venetian blind shading; 2008. 43:197–204. 10.1016/j.buildenv.2006.10.011.
[3] Tzempelikos, A, Athienitis, AK. The impact of shading design and control on building cooling and lighting demand; 2007. 81:369–82. 10.1016/j.solener. 2006.06.015.
[4] Lee, ES, Tavil, A. Energy and visual comfort performance of electrochromic windows with overhangs; 2005. 1–13.
[5] Sabrina B, Kenneth I, Ryan S. Thermal comfort in naturally ventilated buildings with double skin façade under tropical climate conditions: The influence of key design parameters. Energy and Building 2015; 109: 397-406.
[6] Myles E.B, Robert H.C. Directionally selective shading control in maritime sub-tropical and temperate climates: Life cycle energy implications for office buildings. Building and Environment 2016; 104:275-285.
[7] Nedhal A.A, Sharifah F.S.F. The Potential of Shading Devices for Temperature Reduction in High-Rise Residential Buildings in the Tropics. Procedia Engineering 2011; 21:273-282.
[8] China Meteorological Administration (in Chinese). Archived from the original on 2013-09-21. Retrieved August 12, 2016.
[9] Köppen, Wladimir (1884). Translated by Volken, E.; Brönnimann, S. Meteorologische Zeitschrift (published 2011). 20 (3): 351–360
[10] Laura B, Concetta M, Francesco M, Alessia P. An Overview on Solar Shading Systems for Buildings. Energy Procedia 2014; 62:309-317.
[11] Mirrahimi S, Mohamed MF, Haw LC, Ibrahim NLN, Yusoff WFM, Aflaki A. The effect of building envelope on the thermal comfort and energy saving for high-rise buildings in hot–humid climate 2016; 53:1508-1519.
[12] Ayca K, Basak KK, Ioannis C, Sevil S. An integrated thermal and lighting simulation tool to support the design process of complex fenestration systems for office buildings. Applied Energy 2017;198:36-48.
[13] https://www.worldweatheronline.com/guangzhou-weather/guangdong/cn.aspx
[14] Wong Nyuk, H. and D.I. Agustinus. Effects of External Shading Devices on Daylighting and Natural Ventilation, 8th International IBPSA-2003. Netherlands; 2003 ,p. 475–482.