Exergetic Analysis of Steam Turbine Power Plant Operated in Chemical Industry

An Energetic and exergetic analysis is conducted on a
Steam Turbine Power Plant of an existing Phosphoric Acid Factory.
The heat recovery systems used in different parts of the plant are also
considered in the analysis. Mass, thermal and exergy balances are
established on the main compounds of the factory. A numerical code
is established using EES software to perform the calculations
required for the thermal and exergy plant analysis. The effects of the
key operating parameters such as steam pressure and temperature,
mass flow rate as well as seawater temperature, on the cycle
performances are investigated. A maximum Exergy Loss Rate of about 72% is obtained for the
melters, followed by the condensers, heat exchangers and the pumps.
The heat exchangers used in the phosphoric acid unit present
exergetic efficiencies around 33% while 60% to 72% are obtained for
steam turbines and blower. For the explored ranges of HP steam
temperature and pressure, the exergy efficiencies of steam turbine
generators STGI and STGII increase of about 2.5% and 5.4%
respectively. In the same way optimum HP steam flow rate values,
leading to the maximum exergy efficiencies are defined.





References:
[1] Ray T. K., Gupta A., Ganguly R. Exergy-based performance analysis for
proper O&M decisions in a steam power plant. Energy Convers Manage
2010;51:1333–1344.
[2] Hou D., Shao S., Zhang Y., Liu S. L., Chen Y., Zhang S. S. Exergy
analysis of a thermal power plant using a modeling approach. Clean
Tech Policy 2012; 14:805–813.
[3] Regulagadda P., Dincer I., Naterer G. F. Exergy analysis of a thermal
power plant with measured boiler and turbine losses. Appl Therm Eng
2010; 30:970–976.
[4] Erdem H. H., Akkaya A. V., Cetin B., Dagdas A., Sevilgen S. H., Sahin
B., Teke I., Gungor C., Atas S. Comparative energetic and exergetic
performance analyses for coal-fired thermal power plants in turkey. Int J
Therm Sci 2009; 48:2179–2186.
[5] Ghannadzadeh A., Hetreux R. T., Baudouin O., Baudet. P, Floquet P.,
Joulia X. General methodology for exergy balance in ProSimPlus®
process simulator. Energy 2012; 44:38–59.
[6] Molès F. Thermodynamic analysis of a combined organic Rankine cycle
and vapor compression cycle system activated with low temperature heat
sources using low GWP fluids. Appl Therm Eng 2015; 87:444–453.
[7] Taner T. Optimisation processes of energy efficiency for a drying plant:
A case of study for Turkey. Appl Therm Eng 2015; 80:247–260.
[8] Ali Bolatturk, Ahmet Coskun, Caglar Geredelioglu. Thermodynamic
and exergoeconomic analysis of Cayırhan thermal power plant. Energy
Convers and Manage 2015; 101:371-378.
[9] Taillon J., Blanchard R. E., Exergy efficiency graphs for thermal power
plants, Energy 2015; 88: 57-66.
[10] Omendra Kumar Singh, S. C. Kaushik. Energy and exergy analysis and
optimization of Kalina cycle coupled with a coal fired steam power
plant. Appl Therm Eng 2013; 51:787-800.
[11] A. Ganjehkaviri, M. N. Mohd jaafar, P. Ahmadi, H. Barzegaravval.
Modelling and optimization of combined cycle power plant based on
exergoeconomic and environmental analyses. Appl Therm Eng 2014;
67:566-578.
[12] Gupta M. K., Kaushik S. C. Exergy analysis and investigation for
various feed water heaters of direct steam generation solar-thermal
power plant. Renew Energy 2010; 35:1228–1235.
[13] Aljundi I. H. Energy and exergy analysis of a steam power plant in
Jordan. Appl Therm Eng 2009; 29:324–328.