Abstract: Atrial Fibrillation is the most common sustained
arrhythmia encountered by clinicians. Because of the invisible
waveform of atrial fibrillation in atrial activation for human, it is
necessary to develop an automatic diagnosis system. 12-Lead ECG
now is available in hospital and is appropriate for using Independent
Component Analysis to estimate the AA period. In this research, we
also adopt a second-order blind identification approach to transform
the sources extracted by ICA to more precise signal and then we use
frequency domain algorithm to do the classification. In experiment,
we gather a significant result of clinical data.
Abstract: This paper presents a low cost design of heart beat monitoring device using reflectance mode PhotoPlethysmography (PPG). PPG is known for its simple construction, ease of use and cost effectiveness and can provide information about the changes in cardiac activity as well as aid in earlier non-invasive diagnostics. The proposed device is divided into three phases. First is the detection of pulses through the fingertip. The signal is then passed to the signal processing unit for the purpose of amplification, filtering and digitizing. Finally the heart rate is calculated and displayed on the computer using parallel port interface. The paper is concluded with prototyping of the device followed by verification procedure of the heartbeat signal obtained in laboratory setting.
Abstract: In the present study, changes of morphology and
mechanical characteristics in the lumbar vertebrae of the
ovariectomised (OVX) rat were investigated. In previous researches,
there were many studies about morphology like volume fraction and
trabecular thickness based on Micro - Computed Tomography (Micro
- CT). However, detecting and tracking long-term changes in the
trabecular bone of the lumbar vertebrae for the OVX rat were few. For
this study, one female Sprague-Dawley rat was used: an OVX rat. The
4th Lumbar of the OVX rat was subjected to in-vivo micro-CT.
Detecting and tracking long-term changes could be investigated in the
trabecular bone of the lumbar vertebrae for an OVX rat using in-vivo
micro-CT. An OVX rat was scanned at week 0 (just before surgery), at
week 4, at week 8, week 16, week 22 and week 56 after surgery. Finite
element (FE) analysis was used to investigate mechanical
characteristics of the lumbar vertebrae for an OVX rat. When the OVX
rat (at week 56) was compared with the OVX rat (at week 0), volume
fraction was decreased by 80% and effective modulus was decreased
by 75%.
Abstract: This paper presents a novel approach to finding a
priori interesting regions in mammograms. In order to delineate those
regions of interest (ROI-s) in mammograms, which appear to be
prominent, a topographic representation called the iso-level contour
map consisting of iso-level contours at multiple intensity levels and
region segmentation based-thresholding have been proposed. The
simulation results indicate that the computed boundary gives the
detection rate of 99.5% accuracy.
Abstract: The purpose of this study is to derive parameters
estimating for the Lyman–Kutcher–Burman (LKB) normal tissue
complication probability (NTCP) model using analysis of scintigraphy
assessments and quality of life (QoL) measurement questionnaires for
the parotid gland (xerostomia). In total, 31 patients with
head-and-neck (HN) cancer were enrolled. Salivary excretion factor
(SEF) and EORTC QLQ-H&N35 questionnaires datasets are used for
the NTCP modeling to describe the incidence of grade 4 xerostomia.
Assuming that n= 1, NTCP fitted parameters are given as TD50= 43.6
Gy, m= 0.18 in SEF analysis, and as TD50= 44.1 Gy, m= 0.11 in QoL
measurements, respectively. SEF and QoL datasets can validate the
Quantitative Analyses of Normal Tissue Effects in the Clinic
(QUANTEC) guidelines well, resulting in NPV-s of 100% for the both
datasets and suggests that the QUANTEC 25/20Gy gland-spared
guidelines are suitable for clinical used for the HN cohort to
effectively avoid xerostomia.
Abstract: The use of a Bayesian Hierarchical Model (BHM) to interpret breath measurements obtained during a 13C Octanoic Breath Test (13COBT) is demonstrated. The statistical analysis was implemented using WinBUGS, a commercially available computer package for Bayesian inference. A hierarchical setting was adopted where poorly defined parameters associated with a delayed Gastric Emptying (GE) were able to "borrow" strength from global distributions. This is proved to be a sufficient tool to correct model's failures and data inconsistencies apparent in conventional analyses employing a Non-linear least squares technique (NLS). Direct comparison of two parameters describing gastric emptying ng ( tlag -lag phase, t1/ 2 -half emptying time) revealed a strong correlation between the two methods. Despite our large dataset ( n = 164 ), Bayesian modeling was fast and provided a successful fitting for all subjects. On the contrary, NLS failed to return acceptable estimates in cases where GE was delayed.
Abstract: The motivation of this work was to find a suitable 3D
scanner for human body parts digitalization in the field of prosthetics
and orthotics. The main project objective is to compare the three
hand-held portable scanners (two optical and one laser) and two
optical tripod scanners. The comparison was made with respect of
scanning detail, simplicity of operation and ability to scan directly on
the human body. Testing was carried out on a plaster cast of the
upper limb and directly on a few volunteers. The objective monitored
parameters were time of digitizing and post-processing of 3D data
and resulting visual data quality. Subjectively, it was considered level
of usage and handling of the scanner. The new tripod was developed
to improve the face scanning conditions. The results provide an
overview of the suitability of different types of scanners.
Abstract: Thyroid cancer-s overall contribution to the
worldwide cancer burden is relatively small, but incidence rates have increased over the last three decades throughout the world. This trend has been hypothesised to reflect a combination of technological advances enabling increased detection, but also changes in
environmental factors, including population exposure to ionising radiation from fallout, diagnostic tests and treatment for benign and
malignant conditions. The Thyroid dose received apparently shielded
by cerrobend blocks was about 8cGy in 100cGy Expose
Abstract: The γ-turns play important roles in protein folding and
molecular recognition. The prediction and analysis of γ-turn types are
important for both protein structure predictions and better
understanding the characteristics of different γ-turn types. This study
proposed a physicochemical property-based decision tree (PPDT)
method to interpretably predict γ-turn types. In addition to the good
prediction performance of PPDT, three simple and human
interpretable IF-THEN rules are extracted from the decision tree
constructed by PPDT. The identified informative physicochemical
properties and concise rules provide a simple way for discriminating
and understanding γ-turn types.
Abstract: An Automated Rapid Maxillary Expander (ARME) is
a specially designed microcontroller-based orthodontic appliance to
overcome the shortcomings imposed by the traditional maxillary
expansion appliances. This new device is operates by automatically
widening the maxilla (upper jaw) by expanding the midpalatal suture
[1]. The ARME appliance that has been developed is a combination
of modified butterfly expander appliance, micro gear, micro motor,
and microcontroller to automatically produce light and continuous
pressure to expand the maxilla. For this study, the functionality of the
system is verified through laboratory tests by measure the forced
applied to the teeth each time the maxilla expands. The laboratory
test results show that the developed appliance meets the desired
performance specifications consistently.
Abstract: An immunomodulator bioproduct is prepared in a
batch bioprocess with a modified bacterium Pseudomonas
aeruginosa. The bioprocess is performed in 100 L Bioengineering
bioreactor with 42 L cultivation medium made of peptone, meat
extract and sodium chloride. The optimal bioprocess parameters were
determined: temperature – 37 0C, agitation speed - 300 rpm, aeration
rate – 40 L/min, pressure – 0.5 bar, Dow Corning Antifoam M-max.
4 % of the medium volume, duration - 6 hours. This kind of
bioprocesses are appreciated as difficult to control because their
dynamic behavior is highly nonlinear and time varying. The aim of
the paper is to present (by comparison) different models based on
experimental data.
The analysis criteria were modeling error and convergence rate.
The estimated values and the modeling analysis were done by using
the Table Curve 2D.
The preliminary conclusions indicate Andrews-s model with a
maximum specific growth rate of the bacterium in the range of
0.8 h-1.
Abstract: Early breast cancer detection is an emerging field of
research as it can save the women infected by malignant tumors.
Microwave breast imaging is based on the electrical property contrast
between healthy and malignant tumor. This contrast can be detected
by use of microwave energy with an array of antennas that illuminate
the breast through coupling medium and by measuring the scattered
fields. In this paper, author has been presented the design and
simulation results of the bowtie antenna. This bowtie antenna is
designed for the detection of breast cancer detection.
Abstract: The protein domain structure has been widely used as the most informative sequence feature to computationally predict protein-protein interactions. However, in a recent study, a research group has reported a very high accuracy of 94% using hydrophobicity feature. Therefore, in this study we compare and verify the usefulness of protein domain structure and hydrophobicity properties as the sequence features. Using the Support Vector Machines (SVM) as the learning system, our results indicate that both features achieved accuracy of nearly 80%. Furthermore, domains structure had receiver operating characteristic (ROC) score of 0.8480 with running time of 34 seconds, while hydrophobicity had ROC score of 0.8159 with running time of 20,571 seconds (5.7 hours). These results indicate that protein-protein interaction can be predicted from domain structure with reliable accuracy and acceptable running time.
Abstract: The purpose of this research is to compare the original
intra-oral digital dental radiograph images with images that are
enhanced using a combination of image processing algorithms. Intraoral
digital dental radiograph images are often noisy, blur edges and
low in contrast. A combination of sharpening and enhancement
method are used to overcome these problems. Three types of
proposed compound algorithms used are Sharp Adaptive Histogram
Equalization (SAHE), Sharp Median Adaptive Histogram
Equalization (SMAHE) and Sharp Contrast adaptive histogram
equalization (SCLAHE). This paper presents an initial study of the
perception of six dentists on the details of abnormal pathologies and
improvement of image quality in ten intra-oral radiographs. The
research focus on the detection of only three types of pathology
which is periapical radiolucency, widen periodontal ligament space
and loss of lamina dura. The overall result shows that SCLAHE-s
slightly improve the appearance of dental abnormalities- over the
original image and also outperform the other two proposed
compound algorithms.
Abstract: Capacitive electrocardiogram (ECG) measurement is an attractive approach for long-term health monitoring. However, there is little literature available on its implementation, especially for multichannel system in standard ECG leads. This paper begins from the design criteria for capacitive ECG measurement and presents a multichannel limb-lead capacitive ECG system with conductive fabric tapes pasted on a double layer PCB as the capacitive sensors. The proposed prototype system incorporates a capacitive driven-body (CDB) circuit to reduce the common-mode power-line interference (PLI). The presented prototype system has been verified to be stable by theoretic analysis and practical long-term experiments. The signal quality is competitive to that acquired by commercial ECG machines. The feasible size and distance of capacitive sensor have also been evaluated by a series of tests. From the test results, it is suggested to be greater than 60 cm2 in sensor size and be smaller than 1.5 mm in distance for capacitive ECG measurement.
Abstract: A wrist-band type biosignal measurement system and its data transfer through human body communication (HBC) were investigated. An HBC method based on pulses of ultra-wide band instead of using frequency or amplitude modulations was studied and implemented since the system became very compact and it was more suited for personal or mobile health monitoring. Our system measured photo-plethysmogram (PPG) and measured PPG signals were transmitted through a finger to a monitoring PC system. The device was compact and low-power consuming. HBC communication has very strongsecurity measures since it does not use wireless network.Furthermore, biosignal monitoring system becomes handy because it does not need to have wire connections.
Abstract: Enzymatic hydrolysis of starch from natural sources
finds potential application in commercial production of alcoholic
beverage and bioethanol. In this study the effect of starch
concentration, temperature, time and enzyme concentration were
studied and optimized for hydrolysis of cassava (Manihot esculenta)
starch powder (of mesh 80/120) into glucose syrup by immobilized
(using Polyacrylamide gel) a-amylase using central composite
design. The experimental result on enzymatic hydrolysis of cassava
starch was subjected to multiple linear regression analysis using
MINITAB 14 software. Positive linear effect of starch concentration,
enzyme concentration and time was observed on hydrolysis of
cassava starch by a-amylase. The statistical significance of the model
was validated by F-test for analysis of variance (p < 0.01). The
optimum value of starch concentration temperature, time and enzyme
concentration were found to be 4.5% (w/v), 45oC, 150 min, and 1%
(w/v) enzyme. The maximum glucose yield at optimum condition
was 5.17 mg/mL.
Abstract: Various sounds generated in the chest are included in
auscultation sound. Adaptive Noise Canceller (ANC) is one of the
useful techniques for biomedical signal. But the ANC is not suitable
for auscultation sound. Because the ANC needs two input channels as
a primary signal and a reference signals, but a stethoscope can
provide just one input sound. Therefore, in this paper, it was
proposed the Single Input ANC (SIANC) for suppression of breath
sound in a cardiac auscultation sound. For the SIANC, it was
proposed that the reference generation system which included Heart
Sound Detector, Control and Reference Generator. By experiment
and comparison, it was confirmed that the proposed SIANC was
efficient for heart sound enhancement and it was independent of
variations of a heartbeat.
Abstract: The main objective of this research was to investigate
the biosorption capacity for biofilms of sulphate reducing bacteria
(SRB) to remove heavy metals, such as Zn, Pb and Cd from
rainwater using laboratory-scale reactors containing mixed support
media. Evidence showed that biosorption had contributed to removal
of heavy metals including Zn, Pb and Cd in presence of SRB and
SRB were also found in the aqueous samples from reactors.
However, the SRB and specific families (Desulfobacteriaceae and
Desulfovibrionaceae) were found mainly in the biomass samples
taken from all reactors at the end of the experiment. EDX-analysis
of reactor solids at end of experiment showed that heavy metals Zn,
Pb and Cd had also accumulated in these precipitates.
Abstract: Bicycle usage for exercise, recreation, and commuting
to work in Australia shows that pedal cycling is the fourth most
popular activity with 10.6% increase in participants between 2001
and 2007. As with other means of transport, accident and injury
becomes common although mandatory bicycle helmet wearing has
been introduced. The research aims to develop a face surrogate made
of sandwich of rigid foam and rubber sheets to represent human
facial bone under blunt impact. The facial surrogate will serve as an
important test device for further development of facial-impact
protection for cyclist. A test procedure was developed to simulate the
energy of impact and record data to evaluate the effect of impact on
facial bones. Drop tests were performed to establish a suitable
combination of materials. It was found that the sandwich structure of
rigid extruded-polystyrene foam (density of 40 kg/m3 with a pattern
of 6-mm-holes), Neoprene rubber sponge, and Abrasaflex rubber
backing, had impact characteristics comparable to that of human
facial bone. In particular, the foam thickness of 30 mm and 25 mm
was found suitable to represent human zygoma (cheekbone) and
maxilla (upper-jaw bone), respectively.