Abstract: Chlorophytum borivillianum root extract (CBE) was chosen as a reducing agent to fabricate silver nanoparticles with the aim of studying its radioprotective efficacy. The formation of synthesized nanoparticles was characterized by UV–visible analysis (UV–vis), Fourier transform infra-red (FT-IR), Transmission electron microscopy (TEM), Scanning electron microscope (SEM). TEM analysis showed particles size in the range of 20-30 nm. For this study, Swiss albino mice were selected from inbred colony and were divided into 4 groups: group I- control (irradiated-6 Gy), group II- normal (vehicle treated), group III- plant extract alone and group IV- CB-AgNPs (dose of 50 mg/kg body wt./day) administered orally for 7 consecutive days before irradiation to serve as experimental. CB-AgNPs pretreatment rendered significant increase in body weight and testes weight at various post irradiation intervals in comparison to irradiated group. Supplementation of CB-AgNPs reversed the adverse effects of gamma radiation on biochemical parameters as it notably ameliorated the elevation in lipid peroxidation and decline in glutathione concentration in testes. These observations indicate the radio-protective potential of CB-AgNPs in testicular constituents against gamma irradiation in mice.
Abstract: Heat pipe is characterised as superconductor of heat because of its excellent heat removal ability. The operation of several engineering system results in generation of heat. This may cause several overheating problems and lead to failure of the systems. To overcome this problem and to achieve desired rate of heat dissipation, there is need to study the performance of heat pipe with annular fins under free convection at different inclinations. This study demonstrates the effect of different mass flow rate of hot fluid into evaporator section on the condenser side heat transfer coefficient with annular fins under natural convection at different inclinations. In this study annular fins are used for the experimental work having dimensions of length of fin, thickness of fin and spacing of fin as 10 mm, 1 mm and 6 mm, respectively. The main aim of present study is to discover at what inclination angles the maximum heat transfer coefficient shall be achieved. The heat transfer coefficient on the external surface of heat pipe condenser section is determined by experimental method and then predicted by empirical correlations. The results obtained from experimental and Churchill and Chu relation for laminar are in fair agreement with not more than 22% deviation. It is elucidated the maximum heat transfer coefficient of 31.2 W/(m2-K) at 25˚ tilt angle and minimal condenser heat transfer coefficient of 26.4 W/(m2-K) is seen at 45˚ tilt angle and 200 ml/min mass flow rate. Inclination angle also affects the thermal performance of heat pipe. Beyond 25o inclination, heat transport rate starts to decrease.
Abstract: Single phase fluid flow through series of uniform microchannels connected via transition section (converging-diverging section with or without throat) was analytically and numerically studied to characterize the flow within the channel and in the transition sections. Three sets of microchannels of diameters 100, 184, and 249 μm were considered for investigation. Each set contains 10 numbers of microchannels of length 20 mm, connected to each other in series via transition sections. Transition section consists of either converging-diverging section with throat or without throat. The effect of non-uniformity in microchannels on pressure drop was determined by passing water/air through the set of channels for Reynolds number 50 to 1000. Compressibility and rarefaction effects in transition sections were also tested analytically and numerically for air flow. The analytical and numerical results show that these configurations can be used in enhancement of transport processes. However, converging-diverging section without throat shows superior performance over with throat configuration.
Abstract: A mixed method by combining modified pole
clustering technique and modified cauer continued fraction is
proposed for reducing the order of the large-scale dynamic systems.
The denominator polynomial of the reduced order model is obtained
by using modified pole clustering technique while the coefficients of
the numerator are obtained by modified cauer continued fraction.
This method generated 'k' number of reduced order models for kth
order reduction. The superiority of the proposed method has been
elaborated through numerical example taken from the literature and
compared with few existing order reduction methods.
Abstract: A mixed method by combining a Eigen algorithm and improved pade approximations is proposed for reducing the order of the large-scale dynamic systems. The most dominant Eigen value of both original and reduced order systems remain same in this method. The proposed method guarantees stability of the reduced model if the original high-order system is stable and is comparable in quality with the other well known existing order reduction methods. The superiority of the proposed method is shown through examples taken from the literature.
Abstract: Multicarrier transmission system such as Orthogonal
Frequency Division Multiplexing (OFDM) is a promising technique
for high bit rate transmission in wireless communication systems.
OFDM is a spectrally efficient modulation technique that can achieve
high speed data transmission over multipath fading channels without
the need for powerful equalization techniques. A major drawback
of OFDM is the high Peak-to-Average Power Ratio (PAPR) of the
transmit signal which can significantly impact the performance of the
power amplifier. In this paper we have compared the PAPR reduction
performance of Golay and Reed-Muller coded OFDM signal. From
our simulation it has been found that the PAPR reduction performance
of Golay coded OFDM is better than the Reed-Muller coded OFDM
signal. Moreover, for the optimum PAPR reduction performance, code
configuration for Golay and Reed-Muller codes has been identified.
Abstract: Multicarrier transmission system such as Orthogonal
Frequency Division Multiplexing (OFDM) is a promising technique
for high bit rate transmission in wireless communication system.
OFDM is a spectrally efficient modulation technique that can achieve
high speed data transmission over multipath fading channels without
the need for powerful equalization techniques. However the price
paid for this high spectral efficiency and less intensive equalization
is low power efficiency. OFDM signals are very sensitive to nonlinear
effects due to the high Peak-to-Average Power Ratio (PAPR),
which leads to the power inefficiency in the RF section of the
transmitter. This paper investigates the effect of PAPR reduction on
the performance parameter of multicarrier communication system.
Performance parameters considered are power consumption of Power
Amplifier (PA) and Digital-to-Analog Converter (DAC), power amplifier
efficiency, SNR of DAC and BER performance of the system.
From our analysis it is found that irrespective of PAPR reduction
technique being employed, the power consumption of PA and DAC
reduces and power amplifier efficiency increases due to reduction in
PAPR. Moreover, it has been shown that for a given BER performance
the requirement of Input-Backoff (IBO) reduces with reduction in
PAPR.
Abstract: Synthetic juice clarification was done through spiral
wound ultrafiltration (UF) membrane module. Synthetic juice was
clarified at two different operating conditions, such as, with and
without permeates recycle at turbulent flow regime. The performance
of spiral wound ultrafiltration membrane was analyzed during
clarification of synthetic juice. Synthetic juice was the mixture of
deionized water, sucrose and pectin molecule. The operating
conditions are: feed flowrate of 10 lpm, pressure drop of 413.7 kPa
and Reynolds no of 5000. Permeate sample was analyzed in terms of
volume reduction factor (VRF), viscosity (Pa.s), ⁰Brix, TDS (mg/l),
electrical conductivity (μS) and turbidity (NTU). It was observe that
the permeate flux declined with operating time for both conditions of
with and without permeate recycle due to increase of concentration
polarization and increase of gel layer on membrane surface. For
without permeate recycle, the membrane fouling rate was faster
compared to with permeate recycle. For without permeate recycle,
the VRF rose up to 5 and for with recycle permeate the VRF is 1.9.
The VRF is higher due to adsorption of solute (pectin) molecule on
membrane surface and resulting permeateflux declined with VRF.
With permeate recycle, quality was within acceptable limit. Fouled
membrane was cleaned by applying different processes (e.g.,
deionized water, SDS and EDTA solution). Membrane cleaning was
analyzed in terms of permeability recovery.