Paddy/Rice Singulation for Determination of Husking Efficiency and Damage Using Machine Vision

In this study a system of machine vision and singulation was developed to separate paddy from rice and determine paddy husking and rice breakage percentages. The machine vision system consists of three main components including an imaging chamber, a digital camera, a computer equipped with image processing software. The singulation device consists of a kernel holding surface, a motor with vacuum fan, and a dimmer. For separation of paddy from rice (in the image), it was necessary to set a threshold. Therefore, some images of paddy and rice were sampled and the RGB values of the images were extracted using MATLAB software. Then mean and standard deviation of the data were determined. An Image processing algorithm was developed using MATLAB to determine paddy/rice separation and rice breakage and paddy husking percentages, using blue to red ratio. Tests showed that, a threshold of 0.75 is suitable for separating paddy from rice kernels. Results from the evaluation of the image processing algorithm showed that the accuracies obtained with the algorithm were 98.36% and 91.81% for paddy husking and rice breakage percentage, respectively. Analysis also showed that a suction of 45 mmHg to 50 mmHg yielding 81.3% separation efficiency is appropriate for operation of the kernel singulation system.

Disaggregating and Forecasting the Total Energy Consumption of a Building: A Case Study of a High Cooling Demand Facility

Energy disaggregation has been focused by many energy companies since energy efficiency can be achieved when the breakdown of energy consumption is known. Companies have been investing in technologies to come up with software and/or hardware solutions that can provide this type of information to the consumer. On the other hand, not all people can afford to have these technologies. Therefore, in this paper, we present a methodology for breaking down the aggregate consumption and identifying the highdemanding end-uses profiles. These energy profiles will be used to build the forecast model for optimal control purpose. A facility with high cooling load is used as an illustrative case study to demonstrate the results of proposed methodology. We apply a high level energy disaggregation through a pattern recognition approach in order to extract the consumption profile of its rooftop packaged units (RTUs) and present a forecast model for the energy consumption.  

Denitrification of Wastewater Containing High Nitrate Using a Bioreactor System Packed by Microbial Cellulose

A Laboratory-scale packed bed reactor with microbial cellulose as the biofilm carrier was used to investigate the denitrification of high-strength nitrate wastewater with specific emphasis on the effect the nitrogen loading rate and hydraulic retention time. Ethanol was added as a carbon source for denitrification. As a result of this investigation, it was found that up to 500 mg/l feed nitrate concentration the present system is able to produce an effluent with nitrate content below 10 ppm at 3 h hydraulic retention time. The highest observed denitrification rate was 4.57 kg NO3-N/ (m3 .d) at a nitrate load of 5.64 kg NO3- N/(m3 .d), and removal efficiencies higher than 90% were obtained for loads up to 4.2 kg NO3-N/(m3 .d). A mass relation between COD consumed and NO3-N removed around 2.82 was observed. This continuous-flow bioreactor proved an efficient denitrification system with a relatively low retention time.

Nonlinear Dynamic Modeling and Active Vibration Control of a System with Fuel Sloshing

Attitude control of aerospace system with liquid containers may face to a problem associate with fuel sloshing. The sloshing phenomena can degrade the stability of control system and in the worst case, interaction between the attitude control system and fuel vibration leading to resonance. In this paper, a full process of nonlinear dynamic modeling of an aerospace launch vehicle with fuel sloshing is given. Then, a new control system based on model reference adaptive filter is proposed and its algorithm is extracted. This controller implemented on the main attitude control system. Finally, numerical simulation of nonlinear model and control system is carried out to examine the performance of the new controller. Results of simulations show that the inconvenient effects of the fuel sloshing by augmenting this control system are reduced and attitude control system performs, satisfactorily.

Experimental and Theoretical Investigation of Rough Rice Drying in Infrared-assisted Hot Air Dryer Using Artificial Neural Network

Drying characteristics of rough rice (variety of lenjan) with an initial moisture content of 25% dry basis (db) was studied in a hot air dryer assisted by infrared heating. Three arrival air temperatures (30, 40 and 500C) and four infrared radiation intensities (0, 0.2 , 0.4 and 0.6 W/cm2) and three arrival air speeds (0.1, 0.15 and 0.2 m.s-1) were studied. Bending strength of brown rice kernel, percentage of cracked kernels and time of drying were measured and evaluated. The results showed that increasing the drying arrival air temperature and radiation intensity of infrared resulted decrease in drying time. High bending strength and low percentage of cracked kernel was obtained when paddy was dried by hot air assisted infrared dryer. Between this factors and their interactive effect were a significant difference (p

Effect of Influent COD on Biological Ammonia Removal Efficiency

Biological Ammonia removal (nitrification), the oxidation of ammonia to nitrate catalyzed by bacteria, is a key part of global nitrogen cycling. In the first step of nitrification, chemolithoautotrophic ammonia oxidizer transform ammonia to nitrite, this subsequently oxidized to nitrate by nitrite oxidizing bacteria. This process can be affected by several factors. In this study the effect of influent COD on biological ammonia removal in a bench-scale biological reactor was investigated. Experiments were carried out using synthetic wastewater. The initial ammonium concentration was 25mgNH4 +-N L-1. The effect of COD between 247.55±1.8 and 601.08±3.24mgL-1 on biological ammonia removal was investigated by varying the COD loading supplied to reactor. From the results obtained in this study it could be concluded in the range of 247.55±1.8 to 351.35±2.05mgL-1, there is a direct relationship between amount of COD and ammonia removal. However more than 351.35±2.05 up to 601.08±3.24mgL-1 were found an indirect relationship between them.